The device will immediately send a version packet report along with an uplink packet including reed
switch status and battery voltage.
Data will be reported by default setting before any configuration.
Default setting:
Maximum time: 3600s
Minimum time: 3600s (Detect the current voltage value every 3600s by default setting)
Battery Change :0x01 (0.1V)
R311CC status:
When the R311CC status changes, it will send a warning report.
Window/Door sensor open : 1
Window/Door sensor close : 0
The reported data is decoded by the Netvox LoRaWAN Application Command document and
http://loraresolver.netvoxcloud.com:8888/page/index
Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data
report according to Min Interval.
Low Voltage Warning
Low Voltage
2.4V
5.
Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number
between 1~65535
Any number
between 1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval