Changing the link configuration of the SG6000-CN controller
You can change the Ethernet link configuration of the SG6000-CN controller. You can change the
port bond mode, the network bond mode, and the link speed.
Before you begin
•
You must have specific access permissions. For details, see the instructions for administering
StorageGRID.
•
You must be signed in to the Grid Manager using a supported browser.
About this task
Options for changing the Ethernet link configuration of the SG6000-CN controller include:
•
Changing Port bond mode from Fixed to Aggregate, or from Aggregate to Fixed
•
Changing Network bond mode from Active-Backup to LACP, or from LACP to Active-Backup
•
Enabling or disabling VLAN tagging, or changing the value of a VLAN tag
•
Changing the link speed
Before changing the link configuration, you must place the SG6000-CN controller into maintenance
mode. Putting a StorageGRID appliance into maintenance mode might make the appliance
unavailable for remote access.
Steps
1. Follow these steps to place the SG6000-CN controller into maintenance mode:
a. From the Grid Manager, select Nodes.
b. Select the appliance node.
c. Select the Tasks tab.
d. Click Maintenance Mode.
A confirmation dialog box appears.
Maintaining the SG6000 appliance | 97