Viewing error codes for the SG6000-CN controller
If a hardware error occurs when the SG6000-CN controller is booting up, the BMC logs an error
code. As required, you can view these error codes using the BMC interface, and then work with
technical support to resolve the issue.
Before you begin
•
You know how to access the BMC dashboard.
Steps
1. From the BMC dashboard, select BIOS POST Code.
2. Review the information displayed for Current Code and the Previous Code.
If any of the following error codes are shown, work with technical support to resolve the issue.
Code
Indicates
0x0E
Microcode not found
0x0F
Microcode not loaded
0x50
Memory initialization error. Invalid memory type or incompatible
memory speed.
0x51
Memory initialization error. SPD reading has failed.
0x52
Memory initialization error. Invalid memory size or memory
modules do not match.
0x53
Memory initialization error. No usable memory detected.
0x54
Unspecified memory initialization error
0x55
Memory not installed
0x56
Invalid CPU type or speed
0x57
CPU mismatch
0x58
CPU self-test failed, or possible CPU cache error
0x59
CPU micro-code is not found, or micro-code update failed
0x5A
Internal CPU error
0x5B
Reset PPI is not available
0x5C
PEI phase BMC self-test failure
0xD0
CPU initialization error
0xD1
North bridge initialization error
0xD2
South bridge initialization error
0xD3
Some architectural protocols are not available
0xD4
PCI resource allocation error. Out of resources.
0xD5
No space for legacy option ROM
0xD6
No console output devices are found
78 | Hardware Installation and Maintenance Guide for SG6000 Appliances