Controllers in the SG6000 appliances
Each model of the StorageGRID SG6000 appliance includes an SG6000-CN compute controller in a
1U enclosure and duplex E-Series storage controllers in a 2U or 4U enclosure, depending on the
model. Review the diagrams to learn more about each type of controller.
All appliances: SG6000-CN compute controller
•
Provides compute resources for the appliance.
•
Includes the StorageGRID Appliance Installer.
Note:
StorageGRID software is not preinstalled on the appliance. This software is retrieved
from the Admin Node when you deploy the appliance.
•
Can connect to all three StorageGRID networks, including the Grid Network, the Admin
Network, and the Client Network.
•
Connects to the E-Series storage controllers and operates as the initiator.
This figure shows the connectors on the back of the SG6000-CN.
Port
Type
Use
1
Interconnect
ports 1-4
16-Gb/s Fibre Channel
(FC), with integrated optics
Connect the SG6000-CN controller to the
E2800 controllers (two connections to
each E2800).
2
Network ports
1-4
10-GbE or 25-GbE, based
on cable or SFP transceiver
type, switch speed, and
configured link speed
Connect to the Grid Network and the
Client Network for StorageGRID.
3
BMC
management
port
1-GbE (RJ-45)
Connect to the SG6000-CN baseboard
management controller.
4
Diagnostic and
support ports
•
VGA
•
Serial, 115200 8-N-1
•
USB
Reserved for technical support use.
5
Admin Network
port 1
1-GbE (RJ-45)
Connect the SG6000-CN to the Admin
Network for StorageGRID.
SG6000 appliances overview | 11