![NetApp SG100 Hardware Installation And Maintenance Manual Download Page 76](http://html.mh-extra.com/html/netapp/sg100/sg100_hardware-installation-and-maintenance-manual_1669914076.webp)
Code
Indicates
0xF4
MRC: ERR_SET_MC_FREQ
0xF5
MRC: ERR_READ_MC_FREQ
0x70
MRC: ERR_DIMM_CHANNEL
0x74
MRC: ERR_BIST_CHECK
0xF6
MRC: ERR_SMBUS
0xF7
MRC: ERR_PCU
0xF8
MRC: ERR_NGN
0xF9
MRC: ERR_INTERLEAVE_FAILURE
Hardware setup appears to hang
The StorageGRID Appliance Installer might not be available if hardware faults or cabling errors
prevent the appliance from completing its boot-up processing.
Steps
1. Review the LEDs on the appliance and the boot-up and error codes displayed in the BMC.
2. If you need help resolving an issue, contact technical support.
Related tasks
Viewing boot-up codes for the appliance
on page 73
When you apply power to the appliance, the BMC logs a series of boot-up codes. You can view
these codes on a graphical console that is connected to the BMC management port.
Viewing error codes for the appliance
If a hardware error occurs when the appliance is booting up, the BMC logs an error code. As
required, you can view these error codes using the BMC interface, and then work with technical
support to resolve the issue.
Troubleshooting connection issues
If you encounter connection issues during the StorageGRID appliance installation, you should
perform the corrective action steps listed.
Unable to connect to the appliance
If you cannot connect to the services appliance, there might be a network issue, or the hardware
installation might not have been completed successfully.
Steps
1. Try to ping the appliance using the IP address for the appliance :
ping services_appliance_IP
2. If you receive no response from the ping, confirm you are using the correct IP address.
You can use the IP address of the appliance on the Grid Network, the Admin Network, or the
Client Network.
3. If the IP address is correct, check appliance cabling, QSFP or SFP transceivers, and the
network setup.
If that does not resolve the issue, contact technical support.
4. If the ping was successful, open a web browser.
Hardware Installation and Maintenance Guide for SG100 and SG1000 Appliances
76
Troubleshooting the hardware installation