234
Time Zone Commands
clock timezone
Use this command to set the offset to Coordinated Universal Time (UTC). If the
optional parameters are not specified, they will be read as either
0
or
\0
as
appropriate.
The following shows an example of the command.
(CN1610) (Config)# clock timezone 5 minutes 30 zone INDA
no clock timezone
Use this command to reset the time zone settings.
The following shows an example of the command.
(CN1610) (Config)# no clock timezone
show clock
Use this command to display the time and date from the system clock.
The following shows example CLI display output for the command.
(CN1610) # show clock
Format
clock timezone {
hours
} [minutes
minutes
] [zone
acronym
]
Mode
Global Config
Parameter
Description
hours
Hours difference from UTC. The range is -12 to
+13.
minutes
Minutes difference from UTC. The range is 0 to 59.
acronym
The acronym for the time zone. The range is up to
four characters.
Format
no clock timezone
Mode
Global Config
Format
show clock
Mode