NetApp AltaVault Cloud Integrated Storage Installation and Service Guide for Physical Appliances
85
Beta Draft
Replacing the RTC clock coin battery
System maintenance
3.
Hold the battery such that the plus sign on the battery is facing you and away from the battery holder. You must
install the battery in this orientation for the polarity to be correct.
Note:
A plus sign near the battery holder indicates the battery polarity and how the battery should be positioned in the chassis.
4.
Locate the empty battery holder in the controller module and insert the battery into the holder by tilting the battery
at an angle and gently pushing down.
The image below shows the RTC battery in the controller. The battery should slide easily into the battery holder.
If it does not, remove the battery and try again.
5.
Identify battery components as described in this table:
6.
Visually inspect the battery to make sure that it is completely installed into the holder and that the polarity is
correct.
7.
Reinstall the controller module in the chassis, connect power and reboot the system using the steps described in
the procedure,
“Installing a controller in a chassis” on page 64
8.
To ensure that the system has booted correctly, verify that the System attention LED on the chassis front and
Controller attention LED on chassis rear are not lit after the system has finished booting.
Disposing of batteries
Dispose of batteries according to local regulations regarding battery recycling or disposal. If you cannot properly
dispose of the battery, return it to NetApp, as described in the RMA instructions shipped with the kit.
Component
Description
1
RTC battery and controller
Summary of Contents for AltaVault Cloud Integrated Storage 4.1