NetApp AltaVault Cloud Integrated Storage Installation and Service Guide for Physical Appliances
Beta Draft
System maintenance
Replacing internal FRUs
Replacing internal FRUs
To replace internal field-replaceable units (FRUs) inside the AltaVault controller module, you must perform a clean
shutdown of the system, remove the controller module from the chassis, replace the faulty internal FRU, then, re-install
the controller module in the system chassis.
Before you begin, ensure that you replace the impaired controller with a controller module that you received from your
provider.
To replace an internal FRU
1.
Use the
reload halt
command to perform a clean system shutdown of your system.
2.
Power off the system and disconnect the power from the system using the steps described in the procedure,
“Shutting down controllers” on page 60
3.
If
you
are not already grounded, properly
ground yourself
.
4.
Loosen the thumbscrew on the cam handle as shown below.
5.
Identify the components as described in this table:
6.
Pull the cam handle downward to unseat the controller and slide the controller module out of the chassis until it
catches. Then press the release latch on the left side of the controller module and slide the controller module
completely out of the chassis, making sure that you support the base of the module with your free hand.
7.
Place the controller module on a clean, flat surface.
Component
Description
1
Thumbscrew
2
Cam handle