Viewing reports and logs
Viewing the CPU utilization report
The Alarm Status report answers the following question:
What is the current status of the AltaVault?
To view the Alarm Status report
Choose Reports > Alarm Status. Alternately, you can click the current alarm status that appears in the status box
in the upper-right corner of each screen (Healthy, Degraded, or Critical).
Viewing the CPU utilization report
The CPU Utilization report summarizes the percentage of the CPU used within the time period specified.
Typically, the AltaVault operates on approximately 30 to 40 percent CPU capacity during nonpeak hours and
approximately 60 to 70 percent capacity during peak hours. No single AltaVault CPU usage should exceed 95 percent.
The CPU Utilization report answers the following questions:
How much of the CPU is being used?
What is the average and peak percentage of the CPU being used?
Storage Optimization Service
• Storage Optimization Service Down - Enables an alarm and sends an email
notification if the Storage Optimization Service encounters a service condition.
By default, this alarm is enabled. The message indicates the reason for the
condition. The following conditions trigger this alarm:
• Configuration errors: examples include no encryption key set, incorrect
appliance time, or incorrect cloud credentials.
• An AltaVault appliance reboot for example, during an appliance software
update.
• A system crash for example, due to a power failure
• A Storage Optimization Service restart for example, due to a cloud storage
provider change.
• A user enters the CLI command no service enable or shuts down the Storage
Optimization Service from the Management Console
• A user restarts the optimization service from either the Management Console
or CLI
• Storage Optimization Service Error - Enables an alarm and sends an email
notification if the Storage Optimization Service encounters a condition that might
degrade optimization performance. By default, this alarm is enabled.
Storage Optimization Service
Replication
• Replication Error - Enables an alarm when the replication to the cloud encounters
an error. Displays an error message that indicates the type of error such as, a file
cannot be replicated to the cloud.
• Replication Paused - Enables an alarm when the replication to the cloud pauses,
because there is a cloud connection error, or you entered the CLI command no
replication enable, or because you are using replication scheduling
(nonbandwidth limit type). This alarm warns you that the AltaVault is not
replicating data in the cloud.
By default, this alarm is enabled.
System Reserved Space Full
Indicates that the space used for internal data structures is full. If you write more
data to the appliance, it reduces deduplication performance.
Upgrade Status
Indicates the current AltaVault status.
Alarm
Description