![Netafim Fertikit 3G Installation Manual Download Page 12](http://html1.mh-extra.com/html/netafim/fertikit-3g/fertikit-3g_installation-manual_1669784012.webp)
12
FERTIKIT 3G
INSTALLATION MANUAL
DESCRIPTION
PB mode
Operating principle:
The pressure differential required
to generate fertilizer suction via the Venturis is produced
by a booster pump integrated in the FertiKit
TM
.
This mode of operation, where the smaller system pump
is installed upstream from the Venturis, permits the use of a small
booster pump, reducing the investment required and saving energy.
This mode is suitable for relatively low flow rates and pressures.
Flow rate:
5 - 70 m³/h (22 - 300 GPM)
Suitable for main line pressure:
1.5 - 2.5 bars (22 - 36 PSI)
Additional conditions:
The pressure supplied by the dosing booster is added to the main line
pressure. Their sum (in the upper manifold) should not exceed
6.5 bars (94 PSI)
Dosing channels:
Accommodates a wide variety of dosing channels for fertilizer
and concentrated/diluted acid:
•
Up to 4 x 50 - 370 l/h (13 - 100 GPH)
•
Optional - Concentrated acid channel, 50 l/h (13 GPH)
.
Total fertilizer/acid suction capacity - up to 1480 l/h (390 GPH).
Controller:
NMC-Pro, NMC-XL, NMC-Junior, (Other controllers or manual system without controller - optional).
EC/pH:
Single, monitoring and control.
Schematic diagram
22
14
15
13
16
17
18
19
20
21
16
5
8
10
1
2
3
4
6
7
9
11
12
Dosing channel
Scope of delivery
Direction of flow