Grounding and Wiring Recommendations
The LIB-306 can eliminate the effects of noise due to EMI via proper grounding. Always run the ground
connection from the ground screw to the grounded surface before connecting power.
The following wiring considerations are recommended:
Use separate paths to route wiring for power and device data cables. If power wiring and device
data cables must cross, make sure that the wires are perpendicular at the intersection points.
DO NOT run signal or communications wiring and power wiring in the same conduit. To avoid
interference, wire with different signal characteristics should be wired separately.
Keep input and output wires separated.
Label the wiring to all devices in the system for clarity.
No power ON/OFF Switch
: The LIB-306 does not include a power ON/OFF switch; therefore, when power
is applied to the switch, it immediately powers Up.
Back Panel
The LIB-306 back panel is shown and described below.
RESET
: The RESET button functions include:
1)
Press and immediately release the RESET button to :
a. Restart the device.
2)
Press and hold the RESET button for more than 5 seconds to:
a. Load the factory default configuration,
b. copy the running-configuration to the startup-configuration,
c. restart the device in factory default config.
d. Note that this resets the unit IP address.
The RESET button can be disabled (ignored) via the CLI. Refer to the
LIB-306 CLI Reference
manual
.
Note: Restoring factory default can also be performed by making a physical loopback between port 1 and
port 2 within the first minute after switch reboot. In the first minute after boot, 'loopback' packets will be
transmitted at port 1. If a 'loopback' packet is received at port 2, then the switch will do a restore to defaults.
Press the Enter key to display the logon sequence, and then enter your User Name and Password.
DC INPUT
:
-18VDC to -75VDC PSU.
AC Input:
1 x 100-240 VAC; 47-63Hz Auto-sensing PSU