12-Port SDSL Access Multiplexer

INSTALLATION

1. Unpack and inspect the SAM1000-12.

If there is visible damage, do not attempt to connect the device; contact Customer Support at 1-
877-638-2638 (1-603-427-0600 for international customers) or [email protected].

2. Install the SAM1000-12 in an IP DSLAM chassis.

All Access Multiplexer Modules for Net to Net Technologies' IP DSLAMs are hot swappable; 
installing or removing an Access Module while the chassis is powered up does not affect the 
operational status of other Access Modules within the chassis. The IPD12000 is a fourteen slot 
chassis; slots 1-12 are reserved for Access Modules (such as the SAM1000-12) and slots 13-14 
are reserved for Multiplexer Uplink Modules (such as the MUM200-2). Access Modules may be 
placed in any order in slots 1-12. The IPD4000 is a five slot chassis; slots 1-4 are reserved for 
Access Modules and slot 5 is reserved for a Multiplexer Uplink Module.

a. Align the SAM1000-12 with the slot module guides of the chosen slot for installation (slot 

1-12 on the IPD12000 or slot 1-4 on the IPD4000). 

b. Slide the SAM1000-12 firmly into the chassis. DO NOT USE EXCESS FORCE. 

c. Secure the SAM1000-12 by tightening the fastening screws on the module faceplate. 

d. Verify that the PWR (Power) LED on the SAM1000-12 faceplate is illuminated. 

Interface

 Module User Guide

 

CAUTION

Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions 
when handling this equipment. 

NOTE

There must be a Multiplexer Uplink Module installed in the IP DSLAM chassis in order for Access Modules to 
operate.