background image

 

IPD4000E

 

4-Module IP DSLAM: Internet Protocol Digital Subscriber Line Access Multiplexer

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Instructions

© Copyright 2004 Net to Net Technologies, Inc. 

™ The Net to Net Logo is a trademark of Net to Net Technologies, Inc.

Worldwide Headquarters

 

Net to Net Technologies 

112 Corporate Drive 

Portsmouth, NH 03801 

 

USA 

1 (877) 638-2638 

[email protected]

http://www.NetToNet.com

EMEA Headquarters

 

Net to Net Technologies 

Victoria House, 19 Park Way 

Newbury Berkshire RG14 1EE 

 

UK 

44 (0) 1635-570950 

[email protected]

Page 1 of 17

IPD4000E Installation Instructions 220-0000097 rev01 

Summary of Contents for 4-Module IP DSLAM IPD4000E

Page 1: ...rk of Net to Net Technologies Inc Worldwide Headquarters Net to Net Technologies 112 Corporate Drive Portsmouth NH 03801 USA 1 877 638 2638 support nettonet com http www NetToNet com EMEA Headquarters Net to Net Technologies Victoria House 19 Park Way Newbury Berkshire RG14 1EE UK 44 0 1635 570950 support emea nettonet com Page 1 of 17 IPD4000E Installation Instructions 220 0000097 rev01 ...

Page 2: ...al Block 1 5 3 Establish a Power Connection 1 5 3 1 Connect Your Positive Power Lead to the Terminal Block 1 5 3 2 Connect Your Negative Power Lead to the Terminal Block 1 5 3 3 Connect Both Power Leads to a Fuse Panel 1 5 4 Verify the Connection 1 6 Establish Your Uplink Connections 1 7 Connect Your Subscriber Lines 1 7 1 Identify the Appropriate RJ21 Connector s 1 7 2 Detach the Velcro Strap 1 7...

Page 3: ... the air supply vents around the top and bottom edges of the chassis are not blocked CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge ESD precautions when handling this equipment 1 IPD4000E with 1 fan module and 12 blank plates 4 Rubber Bumper Screws 2 Rack Mount Brackets either 19 or 23 as ordered 10 6 Phillips Bracket Screws 8 10 Phillips Rack Screws ...

Page 4: ...your chassis on the rack being utilized Mount the chassis onto the rack and secure the rack mount brackets to the sides of the rack using one of the two provided sets of eight 8 rack screws whichever size fits the rack being utilized Check the rack for stability ensuring that installation of the IPD4000E has not caused the rack to become top heavy RACK MOUNT BRACKET IPD4000E SIDE VIEW Front IPD400...

Page 5: ...t module if redundancy is desired Refer to your management module and or uplink module installation instructions at http www nettonet com support docs for further information 1 3 2 Identify the Appropriate Slot for Installation The IPD4000E is a five slot chassis slots 1 4 are reserved for interface modules and Slot U1 is reserved for a management module The IPD4000E is factory shipped with slots ...

Page 6: ...ducts for a list of available products or contact your Net to Net sales representative for further information Any combination of interface module models may be installed in an IPD4000E as long as they are supported by the model type and version number of your management module refer to the Release Notes for your particular management module model at http www nettonet com support docs for compatib...

Page 7: ... Chassis Tighten the fastening screws on the interface module faceplate by turning them clockwise with a Phillips screwdriver Be careful NOT TO OVER TIGHTEN the screws 1 5 Power Up Your IPD4000E CAUTION If a blank plate is removed from slot 2 4 it must be replaced with an interface module DO NOT OPERATE YOUR IPD4000E WITH AN EMPTY MODULE SLOT Slot Module Guides INTERFACE MODULE Fastening Screws CA...

Page 8: ...ther terminal block on the back of the IPD4000E may be used to power the chassis only one terminal block is required for operational purposes The two terminal blocks on the IPD4000E are independent feeds Chassis power is supplied by only one terminal block at a time the second supply is merely back up Likewise the two terminal blocks do not load share Each terminal block must be supplied with adeq...

Page 9: ...ct Your Negative Power Lead to the Terminal Block Remove the right hand screw labeled from the same terminal block Slide the ring terminal of your NEGATIVE lead around the shaft of the screw and re insert the screw into the same terminal from which it was removed DC Terminal Blocks DC POWER SPECIFICATIONS 48V DC 10 Amps maximum Although actual power draw depends upon chassis configuration a fully ...

Page 10: ...LEAD TO THE NEGATIVE TERMINAL as indicated on your IPD4000E terminal block labels CAUTION The power source s connected to the IPD4000E must be equipped with a disconnect device such as an On Off switch Otherwise an appropriately rated circuit breaker must be installed on each power circuit to be used In the case of an emergency hazardous voltages will not be removed from the IPD4000E until all pow...

Page 11: ...e subscriber connections for interface module ports 1 24 on most models and the RJ21 connectors on the right B provide the subscriber connections for interface module ports 25 48 on applicable models Uplink Module NOTE No configuration is necessary for the interface module s installed in your IPD4000E to operate at default settings However if you wish to run your subscriber connections at settings...

Page 12: ...t on the chassis 1 7 4 Secure the RJ21 Connector Pull the Velcro strap upward making sure that it is snug against the connector then pull the strap back down such that the Velcro layers stick to one another across the top of the connector EXCEPTION For the TIM1500 24 and EIM2000 24 interface modules the A connectors provide the subcriber connections for ports 1 12 and the B connectors provide the ...

Page 13: ...odem will illuminate solid or flashing green to indicate a connection has been established Link up time between interface modules and remote modems can vary from one to five minutes depending on the quality gauge and distance of the copper cable pair s being used Refer to individual interface module user guides at NOTE If you are using a 120 or 180 degree cable both the right and left sides of the...

Page 14: ...ion at http www nettonet com support docs for further information DOCUMENT CONTENTS management module installation instructions model specific module installation port pinouts parameter defaults parameter configuration options management system capabilities uplink module installation instructions model specific module installation port pinouts parameter defaults parameter configuration options int...

Page 15: ...ore of the four fans are no longer functioning 3 2 IPD4000E Interface Capacity 4 interface module slots 1 management module slot 8 RJ21 50 pin female Telco connectors 3 3 Technical Support 3 3 1 Net to Net Technologies Web Site The following information can be found at http www nettonet com support DSL Distance and Bandwidth Quick Reference Chart Firmware Downloads for applicable modules IPD4000E ...

Page 16: ...t installation of this equipment in a rack will not cause the rack to become top heavy or unstable z Do not overload the electrical branch circuit of the power source for this equipment z For tabletop use attach the enclosed rubber feet to the bottom of the chassis z For rack installation attach the enclosed rack mount brackets to the sides of the chassis with the screws provided 3 4 2 Class A Equ...

Page 17: ...ustry Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la Classe A est conforme à la norme NMB 003 du Canada 3 4 2 3 Europe This Class A product complies with European Norm EN55022 Warning In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation Copyri...

Reviews: