www.nerival.fi

 

Safety instructions 

 

 

This manual is intended for use by electrical professionals. All installation 
connections and adjustments must be made in accordance with this instruction 
manual. 

 

Before installation 

Check for transport damages, do not install / use a damaged unit. 
Make sure that the strength and stability of the wall and door structures are 
sufficient.

 

 

Connection 

Only professional electricians are allowed to make electrical connections. 
Make sure the power supply is turned off before making any connections. 
This product must be earthed. 

 

Before turning on the power 

Ensure correct supply voltage 230VAC.  
Make sure that the input and output connections are connected correctly, 
and the connectors are tight. Improper connection can damage the door 
operator. 

 

 

Always switch off the power before installation or maintenance 
and make sure that power is disconnected. 
Read the manual carefully before installing the product. 
Improper installation can be fatal. 
The manufacturer or distributor is not responsible for the 
consequences of incorrect installation or use. 

 

 

 

 

Summary of Contents for NEO-80

Page 1: ...1 www nerival fi User manual AUTOMATIC DOOR OPERATOR NEO 80...

Page 2: ...operator 6 Outward opening door Installation with push arm door operator inside 7 Inward opening door Installation with pull arm door operator inside 8 Connection 9 Button functions 11 Settings 12 Gen...

Page 3: ...ctrical connections Make sure the power supply is turned off before making any connections This product must be earthed Before turning on the power Ensure correct supply voltage 230VAC Make sure that...

Page 4: ...4 www nerival fi Overview Automatic door operator Accessories Dimensions...

Page 5: ...justable Opening angle 0 99 adjustable Supply voltage 230VAC Max power 45W Standby power consumption 2W Remote control distance Over 30m Operating temperature 20 55 Protection class IP12D Dimensions 5...

Page 6: ...6 www nerival fi Installation example Installation of mounting plate and door operator...

Page 7: ...fi Outward opening door Installation with push arm door operator inside Loosen the screws to set the push arm at a 90 degree angle to the door Adjust the limit block in the correct position when the...

Page 8: ...8 www nerival fi Inward opening door Installation with pull arm door operator inside...

Page 9: ...Double door synchronization Synchronization of two door operators COM COM Sensor power supply Sensor output 12VDC Sensor power supply Sensor output 12VDC Sensor signal Sensor signal input Sensor signa...

Page 10: ...he input is active the display shows F3 Access control signal COM Signal opens the door from access control The input is either a voltage signal of 12VDC or a short circuit signal When the input is ac...

Page 11: ...door is closed in the correct position If the device cannot detect the correct stop position the error message E08 is displayed If the door closes in the wrong direction see setting no 9 To skip the...

Page 12: ...greater the angle at which the door closes slowly 7 Closing force 0 10 8 The higher the value the greater the closing force 8 Type of electric lock 0 3 0 0 magnetic lock 1 electric lock 2 fail safe e...

Page 13: ...value the slower the minimum speed 24 Damping compensation 0 4 1 The higher the value the higher the damping force 25 Deceleration ramp 0 5 2 The higher the value the greater the slope 26 Opening angl...

Page 14: ...rol Adding a remote control 1 Go to setting no 10 and press the parameter increase or decrease button 2 Press any key on the remote control 3 The value of the digital display increases by 1 4 The remo...

Page 15: ...ls disabled Error code Cause Solution E0 System error Replace the controller E1 The motor is not connected Check motor connection E2 Motor line failure Check motor connection replace the motor E3 No m...