background image

 

14 

www.nerival.fi

 

Remote control functions 

 

A1: Automatic mode. The door opens when the button 
is pressed and closes normally. 
 
A2: Hold-open mode. The door opens and stays open. 
 
A3: Sensor signal disabled. The door only opens from 
the remote control or access control signal, the sensors 
are not in use. 
 
A4: Sensor and access control signals disabled. 
The door can only be controlled with the remote control. 

 

Adding a remote control 

1.

 

Go to setting no. 10 and press the parameter increase or decrease button.  

2.

 

Press any key on the remote control.  

3.

 

The value of the digital display increases by 1. 

4.

 

The remote control has been added successfully. 

Repeat the above steps to add more remote controls.  
Additional controller e.g. 

Nerival #33340 RCT-1224

 

(Note Additional controller only works in remote control mode 1, see setting no. 17) 
Maximum quantity 40 pcs 

Deleting remote controls 

1.

 

Got to setting no. 21 

2.

 

Set value to 10 

3.

 

Press the Save button 

4.

 

All the remote controls have been successfully deleted. 

 

 

 

 

Summary of Contents for NEO-80

Page 1: ...1 www nerival fi User manual AUTOMATIC DOOR OPERATOR NEO 80...

Page 2: ...operator 6 Outward opening door Installation with push arm door operator inside 7 Inward opening door Installation with pull arm door operator inside 8 Connection 9 Button functions 11 Settings 12 Gen...

Page 3: ...ctrical connections Make sure the power supply is turned off before making any connections This product must be earthed Before turning on the power Ensure correct supply voltage 230VAC Make sure that...

Page 4: ...4 www nerival fi Overview Automatic door operator Accessories Dimensions...

Page 5: ...justable Opening angle 0 99 adjustable Supply voltage 230VAC Max power 45W Standby power consumption 2W Remote control distance Over 30m Operating temperature 20 55 Protection class IP12D Dimensions 5...

Page 6: ...6 www nerival fi Installation example Installation of mounting plate and door operator...

Page 7: ...fi Outward opening door Installation with push arm door operator inside Loosen the screws to set the push arm at a 90 degree angle to the door Adjust the limit block in the correct position when the...

Page 8: ...8 www nerival fi Inward opening door Installation with pull arm door operator inside...

Page 9: ...Double door synchronization Synchronization of two door operators COM COM Sensor power supply Sensor output 12VDC Sensor power supply Sensor output 12VDC Sensor signal Sensor signal input Sensor signa...

Page 10: ...he input is active the display shows F3 Access control signal COM Signal opens the door from access control The input is either a voltage signal of 12VDC or a short circuit signal When the input is ac...

Page 11: ...door is closed in the correct position If the device cannot detect the correct stop position the error message E08 is displayed If the door closes in the wrong direction see setting no 9 To skip the...

Page 12: ...greater the angle at which the door closes slowly 7 Closing force 0 10 8 The higher the value the greater the closing force 8 Type of electric lock 0 3 0 0 magnetic lock 1 electric lock 2 fail safe e...

Page 13: ...value the slower the minimum speed 24 Damping compensation 0 4 1 The higher the value the higher the damping force 25 Deceleration ramp 0 5 2 The higher the value the greater the slope 26 Opening angl...

Page 14: ...rol Adding a remote control 1 Go to setting no 10 and press the parameter increase or decrease button 2 Press any key on the remote control 3 The value of the digital display increases by 1 4 The remo...

Page 15: ...ls disabled Error code Cause Solution E0 System error Replace the controller E1 The motor is not connected Check motor connection E2 Motor line failure Check motor connection replace the motor E3 No m...

Reviews: