39
Nera F77
Continuing the Saturn tradition
Pin
Mne-
Circuit DIN
CCITT Signal
Description
number monic
circuit source
1
CD
109
DCE
Carrier detect
2
RXD
BB
D1
104
DTE
Received Data
3
TXD
BA
D2
103
DCE
Transmitted Data
4
DTR
108
DTE
Data terminal ready
5
GND
102
Signal ground
6
DSR
107
DCE
Data set ready
7
RTS
CA
S2
105
DTE
Request To Send
8
CTS
CB
M2
106
DCE
Clear To Send
9
RI
125
DCE
Ring indicator
5 4 3 2 1
9 8 7 6
The driver used with the RS-232 B (DATA) port can
be switched to be used with the RS-422 (DATA) port
instead, see the User Manual.
TEL
4
ISDN
RS-422
TEL
2
ISDN
ISDN ISDN
ISDN
SILENCE
SW
IND
NMEA
NMEA
TEL
1
TEL
3
ISDN ISDN
TEL 3
USB
RS-232
B
TEL 4
RS-232
A
ISDN
TX
TX
RX
RX
TEL
4
TX
TX
RX
RX
TX
TX
RX
RX
TX
TX
RX
RX
TX
TX
RX
RX
PC serial port
DTE
PC serial port
Max 100 metres
USB port
PC - asynchronous data communication
102 Signal Ground
Digital ground, return line.
103 Send Data
Data transmitted from DTE (PC) to DCE (Nera F77).
104 Receive data
Data Received from DCE (Nera F77) to DTE (PC).
105 Request To Send
OFF requests DCE (Nera F77) to suspend transmission to DTE (PC).
ON requests DCE (Nera F77) to resume transmission to DTE (PC).
106 Clear to send
OFF indicates that DCE (Nera F77) cannot accept data from DTE (PC).
ON indicates that DCE (Nera F77) is prepared to accept data from DTE (PC).
107 Data Set Ready
Signal from Nera F77 that when ON indicates that a data call setup is in progress.
108 Data Terminal Ready
Signal from PC. This signal is used in the Hotline mode and indicate when going from OFF to ON that
the PC wants to make a data call. The PC clears the call by setting the signal from ON to OFF.
109 Receive Signal Indicator
Signal from Nera F77 that when ON indicates that connection is established and received data will be
delivered on circuit 104, Received Data.
125 Ring Indicator
Signal from Nera F77. This signal is used in the Auto answer OFF mode and when ON indicates that
an incoming call is in progress. The signal will go OFF when the call is answered by the PC by turning
circuit 108 Data Terminal Ready ON.
RS-232 connector pin assignments
Signal source DTE means
that the signal goes from the
PC to Nera F77.
Signal source DCE means
that the signal goes from
Nera F77 to the PC.
Signal descriptions
Summary of Contents for F77
Page 53: ......