Neptune HP Turbine Installation And Maintenance Manual Download Page 1

IM TURB 08.08     © Copyright 2008, Neptune Technology Group Inc.     Neptune is a registered trademark of Neptune Technology Group Inc.

neptunetg.com

Neptune Technology Group Inc.

1600 Alabama Highway 229

Tallassee, AL 36078

USA

Tel: (800) 645-1892

Fax: (334) 283-7299

Neptune Technology Group (Canada) Ltd.

7275 West Credit Avenue

Mississauga, Ontario 

L5N 5M9

Canada

Tel: (905) 858-4211

Fax: (905) 858-0428

Neptune Technology Group Inc.

Ejército Nacional No. 418 

Piso 12, Desp. 1201-1202 

Col. Chapultepec Morales 

Delegación Miguel Hidalgo 

11570 México, Distrito Federal 

Tel: (525) 55203 5294 / (525) 55203 5708

Fax: (525) 55203 6503

Summary of Contents for HP Turbine

Page 1: ...llassee AL 36078 USA Tel 800 645 1892 Fax 334 283 7299 Neptune Technology Group Canada Ltd 7275 West Credit Avenue Mississauga Ontario L5N 5M9 Canada Tel 905 858 4211 Fax 905 858 0428 Neptune Technolo...

Page 2: ...ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC H P T U R B I N E I N S TA L L AT I O N A N D M A I N T E N A N C E G U I D E HP Turbine Installation and Maintenance Guide...

Page 3: ...HP Turbine Installation and Maintenance Guide ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC...

Page 4: ...he trade secrets and confidential information of Neptune Technology Group Inc which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part in any form or by...

Page 5: ...E GUIDE iii CONTENTS INSTALLING THE HP TURBINE Installation Instructions 1 1 Recommended Installation 1 1 Before Operation 1 3 MAINTENANCE Adjusting the HP Turbine Calibration Vane 2 2 1 1 2 and 2 HP...

Page 6: ...iv HP TURBINE INSTALLATION AND MAINTENANCE GUIDE NOTES...

Page 7: ...of upstream piping variations or other obstructions in the line When installing Neptune meters with a strainer a minimum of four 4 pipe diameters of straight run pipe can include components that are f...

Page 8: ...ans to field test the meter without removing it from the line When installing HP Turbine meters always follow normal good piping practice Specifically all gaskets should be centrally located on the fl...

Page 9: ...low these steps 1 With outlet side gate valve closed SLOWLY open inlet side valve to pressurize meter 2 SLOWLY open outlet side gate valve until downstream line is pressurized After installation it is...

Page 10: ...1 4 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE NOTES...

Page 11: ...t see Figure 2 1 This unit includes register cover and turbine measuring element Follow these steps 1 Close valves 2 Remove cover bolts 3 Remove UME from maincase 4 Remove old maincase gasket and repl...

Page 12: ...JUSTING THE HP TURBINE CALIBRATION VANE Neptune equips all HP Turbine meters and UMEs with a calibration vane Should the turbine element require field calibration follow these steps 1 1 2 and 2 HP Tur...

Page 13: ...10 or remove lead seal and unscrew register adapter screws 12 20 2 Loosen lock nut on adjusting stem by turning counter clockwise 3 Insert slotted screwdriver into slot in top of adjusting stem and a...

Page 14: ...2 4 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE NOTES...