TSN18358-1 Rev.1 - Page 1
24th December, 2018
MODELS
ACKPWSK
ACKPWSKWM
NEPTUNE KEYPAD TOUCH EM/HID S/ALONE or WIEGAND IP65 (2x6)
NEPTUNE KEYPAD BUTTON MIFARE S/ALONE or WIEGAND IP65 (3X4)
PROGRAMMING
ENTER PROGRAMMING MODE
*
<MASTER CODE> #
CHANGE MASTER CODE
0
<NEW MASTER CODE> # <REPEAT> #
ADD PIN USERS
1
<USER NUMBER (1-2000)> #
<PIN NUMBER> #
1
2
3
1
2
MASTER CODE MUST BE BETWEEN 6-8 DIGITS.
PRESS * TO EXIT PROGRAMMING
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
EXAMPLE
1 1 # 9384 # 2 # 2958 # 3 # 9876 # *
The programming above added 3 users with unique pin numbers
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS
PRESS * TO EXIT PROGRAMMING
ADD CARD USERS
1
<USER NUMBER (1-2000)> #
<BADGE CARD>
1
2
3
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
EXAMPLE
1 1 # <BADGE CARD> 2 # <BADGE CARD> *
The programming above added 2 users with cards
THE ABOVE METHOD IS PREFERRED FOR CARD PROGRAMMING
SO INSTALLERS CAN NOTE WHICH USER NUMBER EACH CARD
IS ASSIGNED TO.
PRESS * TO EXIT PROGRAMMING
DELETE USERS BY USER NUMBER
2
<USER NUMBER (1-2000)> #
1
2
ALL USERS CAN BE DELETED USING THE FOLLOWING STEPS
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS
PRESS * TO EXIT PROGRAMMING
2
0000 #
1
2
SET DOOR RELAY TIME
4
0 # (50ms / 5 seconds)
DEFAULT
1 - 99 # (Another time in seconds)
1
2
PRESS * TO EXIT PROGRAMMING
DELETE USERS BY CARD
2
<BADGE CARD>
1
2
THSI METHOD REQUIRES EXISTING CARD TO BE PRESENT
PRESS * TO EXIT PROGRAMMING
ADD CARD USERS WITH MANAGER CARDS
<BADGE MANAGER ADD CARD>
<BADGE USER CARD BEING ADDED>
1
2
<BADGE MANAGER ADD CARD>
3
THIS METHOD DOES NOT REQUIRE PROGRAMMING MODE
METHOD IS IDENTICAL FOR DELETING USERS WITH MANAGER CARD
Colour Indicators refer to LED status lights on Keypad
NEPTUNE
Quick Reference Guide
DEFAULT MASTER CODE
888888