![Neptune 13458-000 Installation And Maintenance Manual Download Page 40](http://html1.mh-extra.com/html/neptune/13458-000/13458-000_installation-and-maintenance-manual_1668232040.webp)
Electrical Specifications
DC Power (solar or UPS)
12 VDC 0.46 A nominal (1 A peak)
Power Consumption
5.6 W nominal (12 W peak)
Environmental Conditions
Operating Temperature
-22° to 140° (-30° to 60°C)
Storage Temperature
-40° to 185° (-40° to 85°C)
Operating Humidity
0 to 95%
Environmental Rating
NEMA 4X Enclosure
Mechanical Specifications
Maximum Weight
19 lbs. (8.61 kg), with mounting bracket
Dimensions
9.0 W x 13.0 H x 7.5 in. D (22.8 x 33 x 19
cm)
Gateway Stands
Manufacturer
ROHN
Dimensions
5 x 5 ft. square (1.5 x 1.5 m)
Height
10 ft. (304.8 cm)
Pole Diameter
2.375 in (72.4 cm)
Weight (excluding ballast)
50 lbs. (22.6 kg)