![Neptune Technology TRICON SmartTrol Installation And Maintenance Manual Download Page 59](http://html1.mh-extra.com/html/neptune-technology/tricon-smarttrol/tricon-smarttrol_installation-and-maintenance-manual_1668313059.webp)
TRICON
®
SmartTrol
™
Installation and Maintenance Guide
47
Appendix A: Specifications
Appendix A provides the specifications for:
l
TRICON/E
®
.
l
Trident
®
Turbine.
l
HP Turbine.
l
DISC Elements in Compound Meters.
l
TRU/FLO
®
Compound Meter (Turbine Side).
l
Trident
®
PROTECTUS
®
(Turbine Side).
l
HP TRU/FLO
®
Compound Meter (Turbine Side).
l
HP PROTECTUS
®
III (Turbine Side).
l
TRU/MAG™ High Frequency OutPut / K Factor.
l
TRU/MAG™ Pulse Rates.
TRICON/E
®
Performance Data
This section provides performance data for the TRICON/E.
T-10
Size
Max
Flow
(GPM)
Max Continuous
Flow (GPM)
Max Flow
(GPM)
Pulses / Gallon
Pulse Output @
Max Flow
(CPS)
Flow for 20
mA Output
(GPM)
⅝
"
20
10
¼
578.1
192.70
20
¾
"
30
15
½
322.6
161.30
30
1"
50
25
¾
150.8
125.67
50
1½"
100
50
1½
67.57
112.62
100
2"
160
80
2
37.50
100.00
160
Table
19
–
TRICON/E
®
Performance
Data
(T-10)