Neptune ARB
®
V
1
300 feet (91 meters)
Neptune ProRead™ and E-CODER
®
500 feet (152 meters)
Sensus Protocol registers
200 feet (61 meters)
1
Meets manufacturer's published specifications for wire length between encoder
and remote receptacle. The length is based on solid three conductor wire, 22
AWG.
Table 1 – Supported Encoder Maximum Cable Length
Specifications - L900 MIU Pit
Environmental Conditions
This section provides the environmental specifications for the
L900 MIU.
Operating Temperature
-22° to 149°F (-30° to 65°C)
Storage Temperature
-40° to 158°F (-40° to 70°C)
Operating Humidity
0 to 100% Condensing
Table 2 – L900 MIU Pit Environmental Conditions
Functional Conditions
This section provides the functional specification of the L900
MIU.
Register Reading
Eight digits
L900 MIU ID
Nine digits
Table 3 – L900 MIU Pit Functional Specification
Dimensions and Weight
This section provides the dimensions and weight of the L900
MIU.
Dimensions
Refer to Figure 3 and Figure 4
Weight
1.0 lbs. (454 grams)
Table 4 – L900 MIU Pit Functional Specification
4
L900 MIU Pit and Wall Installation and Maintenance Guide
Chapter 2: L900 Specifications
Summary of Contents for L900 MIU Pit
Page 2: ......
Page 3: ...L900 MIU Pit and Wall Installation and Maintenance Guide...