WP-Series Reverse Osmosis System
Installation Instructions and User Manual
Page | - 9 -
Component Identification
1
3
3
10 11
9
12a
5
4
2
12
12b
8
8
7
6
13
12
6
Illustration 2 – System Components
Table 3 - Component Description
#
Item
Description
1.
Controller
Power On/Off and Status Display
2.
Inlet Solenoid Valve
Normally closed. Opens when power is applied.
3.
Cartridge Filter Pressure
Gauges (In-right/Out-left)
Measure the feed and effluent pressure of the cartridge filters. Pressure
difference determines when cartridge change-out is required.
4.
Sediment Filter
5-micron sediment filter.
5.
Carbon
Filter
10-micron extruded carbon cartridge to remove chlorine and reduce organics
from the feed stream.
6.
Low Pressure Switch
Shuts the system down if the inlet pressure is lower than 8 psi (adjustable).
7.
High
Pressure Pump &
Motor
Rotary pump and motor to pressurize the incoming water.
8.
Membrane Modules
RO Membrane elements housed in stainless steel pressure tubes.
9.
System Pressure Gauges
Measure the System (feed) and Concentrate (effluent) pressure of the
membrane modules.
10. Concentrate Control
Valve
To adjust system pressure. Must not be completely closed when the system is
in operation.
11. Recycle Valve
To adjust and maintain adequate flow thru membranes.
12. TDS Monitor
Monitors the feed and permeate water quality.
12a – feed sensor; 12b – permeate sensor
13. Permeate Check Valve
Prevents backflow into RO module.
Summary of Contents for WP Series
Page 31: ...Notes ...