background image

NephSystem Technologies 

 

 

DELTA BC, Canada, V4L 2A6 

Tel: +1 604-9489289  

Fax: +1 604-9489607  

Email: 

[email protected]

 / 

[email protected]

 

 

N320 Ruggedized PDA 

 

Quick Start Guide 

 

v2.2.4 

 

 

 

 

 

 

 

Copyright © 2011 NephSystem Technologies. All Rights Reserved. 

 

Disclaimer and Limitation of Liability 

 

The content of this manual is for information use only and is subject to change without notice. NephSystem Technologies 
assumes no responsibility or liability for any errors or inaccuracies that may appear in this publication. No part of this 
manual may be reproduced in any form or by any means, electronic, mechanical, recording, or otherwise, without the 
prior written permission of NephSystem Technologies. 
 
NephSystem Technologies products are not designed, intended, authorized or warranted to be suitable for life support 
applications or any other life critical applications which could involve potential risk of death, personal injury, property 
damage, or environmental damage. 
 

About NephSystem Technologies 

 

NephSystem Technologies is the leading supplier in the fields of RFID, Smart Tracking Systems and Industrial PDAs. It 
was established in 1998 and has headquarters in Canada and has offices in the Asian-Pacific region. NephSystem 
works with partners around the world to ensure that our customers have the right products and solutions to achieve their 
business goals.  
  
We manufacture and distribute a wide variety of industrial embedded products, Wireless communication devices and 
related peripherals around the world.  

Summary of Contents for N320

Page 1: ...ermission of NephSystem Technologies NephSystem Technologies products are not designed intended authorized or warranted to be suitable for life support applications or any other life critical applications which could involve potential risk of death personal injury property damage or environmental damage About NephSystem Technologies NephSystem Technologies is the leading supplier in the fields of ...

Page 2: ...mail sales nephsystem com service nephsystem com Content 1 Get Understanding of Your N320 PDA 2 Hardware Connection of N320 3 Power On Off and Reset Your N320 PDA 4 Getting Started 5 RFID Operation 6 Barcode Identification 7 GPS Operation 8 GPRS Operation 9 Safety Security Specification ...

Page 3: ...rstanding of Your N320 PDA The NephSystem Technologies N320 PDA package comes with the following components PDA Stylus Mini USB Cable Battery RFID sample tags if the RFID feature is purchased Product CD or a copy of packing list Global 110 220VAC power adapter Please contact us if any of the above mentioned parts is not included in the package ...

Page 4: ... 2 System indicators 3 LCD 3 2 inch Touch Screen LCD the resolution is 240 320 4 Keypad 5 Programmable right key 6 Power Button 7 RESET button can be used to RESET N320 8 Barcode scanner 9 Stylus holder 10 Speaker 11 USB interface 12 Camera 1 3 million pixels camera 13 Flash light of the camera 14 Programmable left key 15 Strap 16 Battery cover Keyboard Description ...

Page 5: ...es DELTA BC Canada V4L 2A6 Tel 1 604 9489289 Fax 1 604 9489607 Email sales nephsystem com service nephsystem com 2 Hardware Connection of N320 Remove the battery cover 2 1 1 2 Insert a TF or Mini SD card If it is needed 2 1 ...

Page 6: ...hSystem Technologies DELTA BC Canada V4L 2A6 Tel 1 604 9489289 Fax 1 604 9489607 Email sales nephsystem com service nephsystem com Insert the SIM card Insert the battery 2 1 Install the battery cover 3 2 1 ...

Page 7: ...NephSystem Technologies DELTA BC Canada V4L 2A6 Tel 1 604 9489289 Fax 1 604 9489607 Email sales nephsystem com service nephsystem com Data Communication cable connection Battery Charger Usage 2 2 1 3 ...

Page 8: ...4 9489607 Email sales nephsystem com service nephsystem com 3 Power On Off and Reset Your PDA Power on Press and hold the power button for 2 to 3 seconds the power indicator will light on automatically and at the same time the startup picture will be displaying on the screen ...

Page 9: ...leeping mode Toggle the power button can wake it up Shut down When you don t need to use the N320 please press and hold the power button for 2 seconds the PDA will pop up with a shutdown message window just click the Yes to shut down immediately at this time the LCD backlight and the power indicator will be off Reset Your N320 PDA Use the stylus to get your N320 reset by pressing the reset button ...

Page 10: ...Windows Mobile Device Center software from 32bit O S http www microsoft com download en details aspx id 14 64bit O S http www microsoft com download en details aspx id 3182 2 Follow the instructions on the webpage to install the software Refer to the Microsoft website for information on how to use the software 3 When you connect your N320 to your computer for the first time the Windows Mobile Devi...

Page 11: ...ActiveSync 2 Follow the setup wizard to set up the partnership Once completed the first synchronization will start automatically 3 The next time you wish to use the synchronization software just plug your N320 into your computer via the USB cable The software will open automatically and update your device 5 RFID Operation s RFID stands for Radio Frequency Identification RFID is the most popular co...

Page 12: ... use RFID testing software along with the products if the RFID feature is selected To make a testing for the RFID please copy the file of NephSystem_320 cab from the product CD over to your N320 click on this cab file on the N320 the testing software will be installed properly on the PDA The RFID antenna zones for different RFID components are located at different areas on N320 For 125 KHz or 134 ...

Page 13: ...L 2A6 Tel 1 604 9489289 Fax 1 604 9489607 Email sales nephsystem com service nephsystem com For 13 56MHz ISOq14443A RFID the antenna zone is located at the keypad area on the front panel see the picture below 13 56MHz RFID 125KHz 134 2KHz RFID ...

Page 14: ...s detailed sample codes etc For more info about the SDK please contact our support team or sales representative for details 6 Barcode Identification NephSystem N320 PDA has optional high performance of barcode scanner It can identify universal barcodes including EAN code 39 code cross 25 code UPC code 128 code 93 code Codabar etc To make a testing for the RFID please copy the file of NephSystem_32...

Page 15: ...please follow the steps below A Get N320 PDA connected with a computer via the ActiveSync copy the GPS demo software of VisualGPSceInstall CAB from the product CD onto any folder on the PDA B Click on the CAB on the N320 for the installation of GPS demo utility C Go to My Device Programs then click VisualGPSce D Click Connect from the menu then choose Serial Port Comm Port ...

Page 16: ...NephSystem Technologies DELTA BC Canada V4L 2A6 Tel 1 604 9489289 Fax 1 604 9489607 Email sales nephsystem com service nephsystem com E Change the Port to COM6 F Select the Baud as 4800 then press OK ...

Page 17: ...7 Email sales nephsystem com service nephsystem com G Or users are able to use the default GPS testing software which is coming with Windows Mobile 6 5 for testing purpose To realize that please got to Start Settings System then click on the icon of GPS Settings see the picture below ...

Page 18: ...489607 Email sales nephsystem com service nephsystem com 8 GPRS Operation To perform a GPRS test please follow the steps below A Go to Start Settings Connections B Then click on the Connections icon on the following screen choose the Add a new modem connection see pictures below ...

Page 19: ...les nephsystem com service nephsystem com C Name a connection then choose Next button D In the Access point name area type in the access point which is being used in your GSM GPRS network for more information about it please work with your ISP to find out and then click Next button to go ahead ...

Page 20: ...607 Email sales nephsystem com service nephsystem com E If required type in the log in information User name and Password on the next window then hit the button of Finish Note To acquire the log in info please work with your ISP for details F The GPRS connection will be ready to go ...

Page 21: ...es implies conformity to the following European Standards 1999 5 EEC Radio Telecommunication Terminal Equipment Directive R TTE EN 301 511 EN 300 328 Specific Absorption Rate SAR Standard EN 50360 EN 50361 73 23 EEC Low Voltage Directive LVD IEC 60950 1 2001 89 336 EEC Electromagnetic Compatibility EMC Directive Standard EN 301489 1 7 17 The manufacturer cannot be held responsible for Modification...

Page 22: ...e cable is broken When the device turns off due to insufficient power supply the mobile phone may be in the inactive state when plugging in the charger for charging Do not try to repair the device The device has no maintainable spare parts If the device is damaged or in the moist environment the device shall be replaced 9 3 About Battery Notice Wrong battery replacement may lead to explosion Pleas...

Page 23: ...NIRP including fixed safety factor and ensure the safety of people at all ages and in any physical state The unit of measurement adopted for the radiation standard of mobile devices is called Specific Absorption Rate SAR The limit value of SAR specified in ICNIRP norms is 2 0W kg per 10g of physical organ on average When measuring SAR standard operation position is adopted meanwhile transmit power...