![Neousys Technology POC-400 Series User Manual Download Page 68](http://html1.mh-extra.com/html/neousys-technology/poc-400-series/poc-400-series_user-manual_1667789068.webp)
POC-400 Series
68
3.7.5
Operation Modes of Ignition Power Control
You can use the rotary switch to configure the operation mode. The system offers 16
(0~15) operation modes with different power-on/power-off delay configurations.
The ignition control module is also BIOS-configurable. When rotary switch is set to
mode 15 (0xF), the ignition power control is set to executed according to parameters
configured in BIOS setup menu, which allows richer combination of power-on/
power-off delay and more detailed control parameters.
Ignition rotary switch
⚫
Mode 0
Mode 0 is the ATX mode without power-on and power-off delay. User can only
use the power button on the front panel to turn on or turn off the system.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
0
N/A
N/A
N/A
⚫
Mode 1
Mode 1 is AT mode without power-on and power-off delay. The system
automatically turns on when DC power is applied. A retry mechanism is
designed to repeat the power-on cycle if the system fails to boot up.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
1
N/A
N/A
N/A
⚫
Mode 2
Mode 2 is designed to have a very minor power on/ off delay of 160ms for
applications that requires the system to start up almost at the same as the rest
of the equipment it is working in collaboration with.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
2
160ms
160ms
10 minutes
Summary of Contents for POC-400 Series
Page 1: ...Neousys Technology Inc POC 400 Series User Manual Revision 1 0...
Page 4: ...Table of Contents 4 GetStatusPoEPort 97 EnablePoEPort 98 DisablePoEPort 99...
Page 16: ...POC 400 Series 16 1 3 Dimension 1 3 1 Superior View 1 3 2 Front Panel View...
Page 17: ...POC 400 Series 17 1 3 3 Bottom View...