![Neousys Technology Nuvo-6000 Series User Manual Download Page 18](http://html.mh-extra.com/html/neousys-technology/nuvo-6000-series/nuvo-6000-series_user-manual_1667804018.webp)
Nuvo-6000 Series User’s Manual
Copyright © 2016 Neousys Technology Inc. All Right Reserved.
Page 18 of 100
2.2.10 3-Pin Terminal Block for DC Input
Nuvo-6000 series allows a wide range of DC power input from
8 to 35V via a 3-pin pluggable terminal block, which is fit for
field usage where DC power is usually provided. And the
screw clamping connection of the terminal block gives a very
reliable way of wiring DC power. For detail information of
supplying DC power via pluggable terminal block, please refer
to section 3.9.
Caution
1.
Please make sure the voltage of DC power is correct before you connect it to Nuvo-6000
controller. Supplying a voltage over 35V will damage the system.
Symbol
Description
Chassis ground (connect to the earth ground)
GND
Negative polarity (ground) of DC input
V+
Positive polarity of DC input