Neomatica, LLC. Terminal ADM700 3G GLONASS/GPS. Ed. 7.2, dd.  24.11.2018

 

80 

Appendix D. ISO 9001:2015 

 

 

 

 

Summary of Contents for ADM700 3G

Page 1: ......

Page 2: ...RS sensor 28 7 4 3 Working with RFID reader ADM20 30 7 5 Interface RS 232 31 7 5 1 Fuel level sensors connection 32 7 5 2 Photo camera connection 33 7 5 3 CAN LOG connection 34 7 5 4 Autotracker fuel...

Page 3: ...ransportation requirements 72 14 Warranty 72 15 Marking and packaging 73 16 Disposal 73 17 Scope of supply 73 Appendix Bits description for the STATUS field 74 Appendix B WIALON system parameters desc...

Page 4: ...and who have special professional knowledge in electronic and electric equipment used on various transport means The tracker proper work can be guaranteed if it is installed and set by qualified profe...

Page 5: ...transmission to a dedicated server with static IP address or domain name which these data might be received from through the Internet for further analysis and processing in the operator s console The...

Page 6: ...allowing for a quality routing recording any changes without a surfeit of information saved in the black box and increase in GPRS traffic The tracker with the GLONASS GPS module ensures time and navig...

Page 7: ...00 GPRS EDGE Multi slot Class 12 HSDPA 3GPP release 5 GSM transmitter power 2 W Number of SIM cards 2 or 2 SIM chips optional Number of analogue inputs 6 AIN0 analogue input features voltage measureme...

Page 8: ...l In built anti tamper switch Battery Li Pol 1000mA h 3 7 V 3 7 W h Memory card slot MicroSD 1 Ingress protection class IP65 Mechanical impact protection class IK07 Number of route records saved when...

Page 9: ...oice call receiving and voice connection setting For data transmission GSM GPRS module establishes and maintains connection to the server and from time to time transmits information packets Time of da...

Page 10: ...y cutoff blinks three times GSM module is switched off for reinitialization blinks twice GSM module is switched on but there is no connection to the server blinks once the tracker has installed connec...

Page 11: ...Neomatica LLC Terminal ADM700 3G GLONASS GPS Ed 7 2 dd 24 11 2018 11 Figure 2 Contacts arrangement 12 U vehicle electrical system...

Page 12: ...reviewed by this Operation manual technical requirements or other documents describing the tracker operation to use the tracker in cases which may cause its damage harm its energy supply systems affec...

Page 13: ...en and blue LED will have been blinking many times during five seconds When there are valid data from satellites and the connection to the server is installed the tracker will identify time coordinate...

Page 14: ...layout for the tracker power supply 12 U vehicle electrical system 6 Tracker setting The tracker is controlled by means of commands sent via SMS GPRS or USB General rules for writing commands only La...

Page 15: ...ord 0 it is not necessary to enter the password No authorization is required for configuration via GPRS 6 1 Phone number authorization To handle the tracker via SMS commands it is necessary to send th...

Page 16: ...ents per inputs OUTS 4 Analogue inputs IN_A 8 Pulse inputs IN_D 16 Fuel level sensors FUEL 32 Can CAN 64 Odometer value ODOMETR 128 6 4 Setting coordinates freezing during a parking The margin of erro...

Page 17: ...the microSD memory card as a black box The tracker allows using the microSD memory card as a black box for saving data transmitted to the telematic server For this it is necessary to put the memory c...

Page 18: ...the fact of a certain voltage presence for example in the ignition activation circuit it might be necessary to set for the selected analogue input voltage levels for the logical 0 by the INFALSE comma...

Page 19: ...ency meter mode IMPULSE 1 1 pulse inputs in the Flowmeter mode IMPULSE 1 2 pulse inputs in the Differential flowmeter mode IMPULSE 3 3 pulse inputs in the Discrete input mode Frequency meter Flowmeter...

Page 20: ...5 Connection layout for fuel level frequency output sensor 12 U vehicle electrical system 7 2 2 Flowmeter mode Flowmeter mode allows counting pulses and saving data in the non volatile memory A layou...

Page 21: ...flowmeters installed in direct and reverse fuel supply line The direct supply flowmeter should be connected to the input DIN0 and the reverse supply flowmeter to the input DIN1 Calculation is made ac...

Page 22: ...The discrete input might be used to control condition of equipment having the open collector type output or to control condition of equipment switched ON and OFF according to the ground Discrete inpu...

Page 23: ...tes the logical 1 is transmitted during the open circuit state in a disconnected condition the logical 0 during the close to ground state vehicle electrical system minus A layout for a door limit swit...

Page 24: ...posure to self induction pulses which appear after switching off the inductive load including the relay coil it is necessary to connect a diode in parallel to the relay coil in the opposite direction...

Page 25: ...Neomatica LLC Terminal ADM700 3G GLONASS GPS Ed 7 2 dd 24 11 2018 25 Figure 9 Connection layout of a relay to the tracker discrete output 12 U vehicle electrical system...

Page 26: ...screte output 12 U vehicle electrical system To enhance driving safety it is possible to use the tracker output for connecting a light and a sound alarm which work off during an over speed a rapid acc...

Page 27: ...level sensors to the RS 485 bus The tracker interrogates sensors one by one and transmits fuel level and temperature values in the FUEL data block Before connecting to the tracker it is necessary to s...

Page 28: ...n is performed with the RS 485 interface Sensor readings are transmitted instead of data from CAN bus It is necessary to activate the CAN data block with the PROTOCOL command It is possible to transmi...

Page 29: ...mmand deactivates the sensor request and parameters transmission to the server Table 2 EUROSENS DELTA RS sensor readings available for transmission Requested data code Field 1 Field 2 0x00 Fuel amount...

Page 30: ...de duration sec Supply chamber cheat mode duration sec 0x1C Backward chamber idle mode duration sec Backward chamber nominal mode duration sec 0x1D Backward chamber overload mode duration sec Backward...

Page 31: ...e 12 U vehicle electrical system 7 5 Interface RS 232 Depending on the equipment to be connected it is necessary to configure the operating modes of the ports RS 232 0 and RS 232 1 This setting is per...

Page 32: ...1 CAN LOG 7 5 1 Fuel level sensors connection To connect fuel level sensors it is necessary to do the following disable automatic data output in the sensor settings set the data transmission speed to...

Page 33: ...cle electrical system 7 5 2 Photo camera connection To connect the camera do the following install a microSD memory card microSD memory cards up to 32GB with FAT32 file system are supported connect th...

Page 34: ...a series If Y 0 the photo taking will stop only when a logical 0 appears on the selected analog input Z is the time between photo takings in seconds It is also necessary to set the range for the logic...

Page 35: ...ation mode with CAN LOG enable transmission of the CAN data block with the PROTOCOL command or in the graphical interface of the ADMConfigurator program Figure 14 Connection layout of CAN LOG to the R...

Page 36: ...1 RS232_1 Y 2 RS485 If necessary readings transmission from the tachograph odometer should be enabled instead of the readings from the built in odometer of the tracker via the command TACHOTRODOMETR X...

Page 37: ...and the microphone sensitivity by the VOLUME command 7 7 1 Wire bus Up to 8 temperature sensors can be connected to the 1 Wire bus To do this you should do the following connect the temperature sensor...

Page 38: ...he necessary setup and connection are performed the device will play the sound files recorded on the memory card when entering the specified zones During the movement the tracker checks the current ge...

Page 39: ...ts And also requires less space for installation But it has limitations for the output power the number and characteristics of the connected loudspeakers To connect the loudspeakers to an amplifier bu...

Page 40: ...s method provides the freedom of choice in relation to the required output power and the number of loudspeakers because it is possible to select an amplifier with necessary characteristics It also all...

Page 41: ...to tracker line output 8 2 Routes planning To plan routes it is necessary to do the following 1 Format microSD memory card into FAT32 file system MicroSD memory cards up to 32 Gb are supported 2 Make...

Page 42: ...must contain only English alphabet characters and numbers 5 Open route txt file in text editor Create descriptions of geographical areas and connect necessary audio files with each geographical area...

Page 43: ...to the tracker microSD memory card having being adopted as regards clause 8 2 switch on the tracker choose current route using ROUTE X command where X is a route name if there is a necessity test how...

Page 44: ..._L 9 21 contacts of MF 24F plug Use connection layout given in Figure 20 while connecting to diagnostic outlet If in the connection point to the bus between lines CAN_H and CAL_L there is resistance o...

Page 45: ...Neomatica LLC Terminal ADM700 3G GLONASS GPS Ed 7 2 dd 24 11 2018 45 Figure 20 Connection of tracker to CAN bus diagnostic connector 12 U vehicle electrical system...

Page 46: ...Neomatica LLC Terminal ADM700 3G GLONASS GPS Ed 7 2 dd 24 11 2018 46 Figure 21 Connection of tracker directly to Can bus 12 U vehicle electrical system...

Page 47: ...om CAN bus you should use ADMConfigurator program of version 2 1 and higher To set messages receipt from CAN bus do the following open division Sensors CAN press Switch on CAN press Apply settings Whe...

Page 48: ...a whole list of identifiers being transmitted in a connected CAN bus will be created You may choose any identifier from this list and add it for monitoring having changed mask if necessary For this yo...

Page 49: ...hin the pre set range in the analogue input For this function it is necessary to set SMS sending condition according to the event in the input by the INTRUESMS command and the message text by the INTR...

Page 50: ...1 2 3 PHONES 0 1 2 79876543210 3 X password by default 0 Y 0 3 memory box number for the phone number saving This parameter is not compulsory Authorization of the phone number which the SMS was receiv...

Page 51: ...umber of data package Time current GMT time and date Nav coordinates validity Lat latitude Lon longitude Speed speed SatCnt number of satellites Stat status 7 IMEI Example IMEI IMEI Example IMEI 35958...

Page 52: ...port which the tracker is connected to for data transmission The command without parameters restores to the current server address and port 11 DN0 X Y Example SETHOST0 www test ru 1000 HOST0 X Y Examp...

Page 53: ...X Y Example VOLUME 75 10 VOLUME X Y Example VOLUME 75 10 X 0 100 loudspeaker loudness value Y 0 15 microphone sensitivity Setting of loudspeaker loudness and microphone sensitivity Command without pa...

Page 54: ...ackets memory during traveling and parking The command without parameters restores to current settings 19 OUTPUT X Y Example OUTPUT 1 1 OUTPUT 3 0 Example OUTPUT 3 0 0010 X 0 3 output number Y 1 outpu...

Page 55: ...ting operation modes for pulse inputs X 0 Y 0 input activated in frequency meter mode X 1 Y 1 input activated in flowmeter mode X 1 Y 2 input IN6 activated in differential flow meter mode id est the f...

Page 56: ...t was cleared Removing all numbers from the list of phone numbers for SMS sending 27 EventListShow Event list 0 779876543210 1 79876543211 2 79876543212 3 Viewing the list of phone numbers for sending...

Page 57: ...lt Y 0 Xmin 0V Xmax 0V Y 1 Xmin 0V Xmax 0V Y 2 5 Xmin 0V Xmax 0V 30 InTrueSmsText X Y Input Y TrueSms X Y 0 5 input number X text message no longer than 10 characters Sending SMS text t when input vol...

Page 58: ...ode Example Input 0 on guard mode X 0 5 input number Setting the input number for guard mode activation the command without X parameters restores to the current input number for guard mode activation...

Page 59: ...ple GPSAlarmText The car moves X text message not exceeding 20 characters Setting a text message transmitted during the movement of the vehicle in guard mode 41 42 MODE X Example MODE 1 RELOAD MODE X...

Page 60: ...when the number of satellites is fewer than X they will be transmitted as invalid 46 MAXHDOP Example MAXHDOP 5 5 MAXHDOP X Example MAXHDOP 5 5 X the maximum HDOP value By default X 50 0 Setting the l...

Page 61: ...n the protocol Setting of protocol type and format NAVIGATION DATA 0 basic data OUTS 4 outputs events by inputs IN_A 8 analogue inputs IN_D 16 pulse inputs FUEL 32 fuel level sensors ODOMETR 128 virtu...

Page 62: ...will be being substituted by the transmission of coordinates freezing state 55 TEMPTOIN X Example TEMPTOIN 2 TEMP CONNECT TO INPUT X Example TEMP CONNECT TO INPUT 2 X 0 5 input number X 255 sensor is...

Page 63: ...deactivated when the speed is fewer than X so that there wouldn t be too many points at low speed values This parameter change might cause improper function of the tracker 60 STATMASK X Example STATMA...

Page 64: ...IN0 1234 X PIN code Setting SIM card PIN code Command without parameters does not display current code 64 PIN1 X PIN1 1234 PIN1 X PIN1 1234 X PIN Setting SIM card PIN code Command without parameters d...

Page 65: ...X Example PSTATIC 1 PSTATIC X Example PSTATIC 1 X 1 program statics function enabled X 0 program statics function disabled Coordinates freezing function on off during the parking by the program metho...

Page 66: ...is relevant default value Setting of data uploading order from the black box to the telematics server When using a memory card as a black box the uploading order is only on time X 1 77 CAMENABLED X Ex...

Page 67: ...ample EGTSEVENTSRC 2 13 EGTSEVENTSRC X Y Example EGTSEVENTSRC 2 13 X 0 5 input number Y value put in the src field Installing the input number which will initiate formation of an extraordinary packet...

Page 68: ...DE X Y Z A B Example ADM20MODE 0 2 0 2 0 ADM20MODE X Y Z A B enabled Example ADM20MODE 0 2 n a 2 n a enabled X 0 4 setting reader number Y 0 2 setting mode number Z card checking period A 0 5 analogue...

Page 69: ...TRCARDNUMBER X Example TACHOTRCARDNUMBER 1 X 0 function disabled X 1 function enabled Switching on transmission of driver s card number instead of data from AIN4 and AIN5 analogue inputs 97 TACHOTRODO...

Page 70: ...ple OWTHERMOENABLED 1 OWTHERMOENABLED X Example OWTHERMOENABLED 1 X 0 function disabled X 1 function enabled Switching on sensors data transmission instead of analogue inputs data 102 OWTHERMO X Examp...

Page 71: ...otifications press firmware upgrade via USB after being upgraded the tracker will be rebooted and become available for work WARNING Don t switch the tracker power off when upgrading the tracker firmwa...

Page 72: ...dress settings installed before upgrading The remained settings should be checked after upgrade and if necessary re install them Depending on the GSM network the upgrading process takes on average fro...

Page 73: ...site http en neomatica ru upload files license pdf 15 Marking and packaging Marking is placed on the tracker housing The trackers are packed in individual boxes which protect them during transportati...

Page 74: ...M1 2 2 No connection to the server 4 3 Guard mode enabled 8 4 Battery low voltage indicator 16 5 Invalid coordinates indicator validity 32 6 Coordinates are frozen during parking 64 7 Tracker external...

Page 75: ...el value in sensor No 0 connected via RS 485 interface fuel2 Fuel level value in sensor No 1 connected via RS 485 interface fuel3 Fuel level value in sensor No 2 connected via RS 485 interface temp1 T...

Page 76: ...er supply off in17 Alarm went OFF in18 Cutoff failure of GPS GLONASS antenna in19 Short circuit of GPS GLONASS antenna in20 High power supply voltage indicator in21 microSD card used as black box in22...

Page 77: ...tal time of engine operation 0 1 hour can4 C_distance Total run km can5 G_level Fuel level 0 1 liter 0 1 can6 S_flag Status flags see below can7 P_alarm Accident controllers see below can8 K_axis load...

Page 78: ...4 hood opened 5 hand brake 6 foot brake 7 engine enabled 8 webasto 9 ignition is on 10 standard alarm alarm mode 11 standard alarm 12 key is in the ignition lock 13 Dynamic ignition 14 15 16 informat...

Page 79: ...3 4 5 6 7 passenger s belt 8 driver s belt 9 ESP 10 heating plug 11 FAP 12 EPC 13 marker lamps 14 passing beam 15 Main beam 16 17 check engine 18 external lighting 19 pressure in cans 20 brake blocks...

Page 80: ...Neomatica LLC Terminal ADM700 3G GLONASS GPS Ed 7 2 dd 24 11 2018 80 Appendix D ISO 9001 2015...