47
10.2 Component Positions Setup
(
Note:Password is required to activate the items to avoid misoperation, please contact technical engineer before
calibrating.
)
1. Fiducial Camera Relative Position
Put a piece of label paper on the side of the track and dip the nozzle 1 into the printing paste or ink.
Go to the Manual Test interface, click “XY Move” , use the reference camera find the location of the label paper(find the
location of the label on the track surface), for align way ,choose “nozzle 1”, and then click “close and back”. Go to the
System Setup interface, after administrator login, “click to align” on Fiducial Camera Relative Position. A prompt window
will pop up, “If continue to leave trace at current position?” After clicking “Yes” to enter this interface (see Figure ), then
click “Nozzle 1 Trail”, the nozzle will move downwards and rotate until get a round mark. Follow the same steps to get the
trail of Nozzle #8 , then check the offset between the round mark and the red crosshair, if it’s within 0.1mm, the trail is