![NEO HS2016 User Manual Download Page 11](http://html.mh-extra.com/html/neo/hs2016/hs2016_user-manual_718761011.webp)
Chapter 4.0 Arming the System
5.
To cancel the arming sequence, enter your [access code] or
present your proximity tag to the keypad reader.
System Disarmed
No Alarm Memory
6.
Once the exit delay timer expires, thereby arming the system,
the:
l
Ready indicator turns off.
l
Armed indicator remains on.
l
Keypad stops sounding.
System Armed
in Away Mode
Note:
The installer configures the exit delay timer and whether or not an access code is required
for arming the system.
4.3 Exit Delay Time Restart
The control panel provides an option where, if a entry/exit zone is tripped a second time prior to the
end of the exit delay, the exit delay time restarts. The exit delay timer can only be restarted once.
4.4 Alarm Cancel Window
The control panel provides a period of time in which the user can cancel the alarm transmission. If
the programmed alarm transmission delay has expired, canceling an alarm sends a message to the
monitoring station. Upon a successful transmission of the cancellation message the keypad will beep
6 times.
Note:
Must be enabled and configured by installer.
Note:
For CP-01 systems, alarm transmission delay must not exceed 45 seconds.
4.5 Using 2-way Wireless Keys and Proximity Tags
2-way wireless keys allow users in the close proximity of their house the ability to readily arm/dis-
arm their system, and to call for help. For information on enrolling wireless keys see "User Labels
(LCD keypads only)".
6
7
1
2
3
4
5
5
2
3
4
1
6
1.
Away Arm
2.
Stay Arm
3.
Disarm
4.
Panic
5.
Command Output 1
6.
Message LED
7.
Status LEDs
1.
Away Arm
2.
Stay Arm
3.
Disarm
4.
Panic
5.
Command Output 1
6.
LED
Note:
Panic feature has not been evaluated by UL. All wireless key buttons are programmable.
Verify the functions assigned to each key with your installer. When using compatible wireless keys
there is one bell squawk for arming and two bell squawks for disarming.
- 10 -