5.5 FK and FF bearings
5.5.1 FF bearing (loose)
Article Nr.
Description
Quantity
1
Z-base plate
1
2
FF bearings (loose bearings)
1
3
M3 x 12 mm flat head screw
4
Pass the FF bearing block (loose bearing) through the ball screw.
Attach the FF bearing block to the Z-base plate with 4x M3 x 12mm flat head screws.
When tightening the screws, tighten all screws completely, then loosen them by 2 turns. This part is