background image

 

15

 

Agri xJ 

Installation notes 

 
 

INSTALLATION NOTES 

 

 

Keep the wires to the fence separate from the battery wiring.  

 

Do  not  try  and  modify  the  energizer.  Any  unauthorized  modifications  will 
null and void the warranty and possibly render the unit illegal.  

 

Use HT (high voltage) wire between the fence and energizer, including the 
earth wire. Never run these wires in the same conduit or through the same 
hole as the low voltage wiring. 

 

Always  use  ferrules  or  line  clamps  to  connect  two  high  voltage  wires 
together.  Avoid  using  dissimilar  materials  for  connections  like  copper  on 
steel. 

 

The  fence  must  be  earthed  properly  with  three  earth  electrodes  close  to 
the  energizer.  The  distance  between  the  fence  earth  electrode  and  any 
other  earth  systems  shall  be  not  less  than  2m  for  a  security  fence 
installation.  (Typically  a  suburban  property  installation)  ,  and  10m  for  an 
agricultural fence installation. (Typically a rural property installation.) 

 

Refer to the applicable laws concerning the installation of electric fences in 
your area. 

 

Summary of Contents for AGRI xJ

Page 1: ...AGRI xJ Electric Fence Energizer Instruction Manual Revision 0 0 10 September 2011 GROUP OF COMPANIES ...

Page 2: ...ymbol key 7 Energizer details 8 Energizer features 9 Product specification 10 Operating without a key chain remote 11 Using the Nemtek key chain remote 12 Operating with a key chain remote 13 14 Installation notes 15 Appendix 16 18 Document revision history 19 No user serviceable parts inside the energizer ...

Page 3: ...curity industry since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to South African and international standards in order to ensure the highest quality products and continuous customer satisfaction Electric fencing can be lethal ...

Page 4: ...ts The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse LIMITATION OF GUARANTEE The guarantee does not apply to defects resulting from acts of God modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are IO Tech Manufacturing Pty Ltd s sole ...

Page 5: ...dowdale Edenvale NEMTEK Cape Town 27B Concord Crescent Tel 27 0 21 386 3742 Airport City Fax 27 0 21 386 5573 Cape Town NEMTEK Nelspruit Waterval Ave Tel 27 0 13 752 2187 Riverside Industrial Fax 27 0 13 752 2188 Nelspruit NEMTEK KwaZulu Natal Unit 30 Devon Park Tel 27 0 31 701 2125 11 Devon Road Fax 27 0 31 701 2125 Pinetown Website www nemtek com E mail nemtek nemtek com Manufactured in South Af...

Page 6: ... against theft of the energizer The Agri xJ range of energizers incorporate our advanced and patented fence voltage control system referred to as Adaptive Power Technology or APT What this means is the fence energy is maintained at a higher level than would normally be achievable using a conventional energizer on the same fence when factors such as poor or damaged insulators wet insulators after a...

Page 7: ...e Earth connection terminal High Voltage Fence Live connection terminal Symbols on the Nemtek key chain remote body Transmission Communication target on the remote Right Triangle Right button Left Triangle Left button Square Centre button Symbols in the remote menu Sun represents day operating mode Moon represents night operating mode ...

Page 8: ...High intensity pulse rate warning Light Battery State Mounting Clip Day Night Sensor Battery Battery Fence ground Fence High Voltage Connection Connection Comment SA7 Correct rendering with decal in place and black colored plastic to be placed here ...

Page 9: ...ndication green charged yellow low red discharged Accurate battery voltage reporting through the Nemtek key chain remote Accurate fence voltage reporting through the Nemtek key chain remote Energizer effort reporting through the Nemtek key chain remote Nemtek Security Lock Lowest recorded fence voltage memory Highest recorded energizer effort memory Energizer factory default settings Fence voltage...

Page 10: ...x 190 x 76 Environmental rating IP 65 IP 65 IP 65 Weight 0 8 Kg 0 85 Kg 0 9 Kg When operating at 50 capacity Typical operating time from a new charged 12V 7Ah SLA battery Model Pulse Rate Fence Set Voltage Typical Supply Current Typical Energizer Effort Running Time Agri J 1 second 9 kV 0 1 A 60 100 hours Agri 1 J 1 second 9 kV 0 1 A 30 100 hours Agri 2 J 1 second 9 kV 0 1 A 15 100 hours Agri J 1 ...

Page 11: ...will begin operating at 9 kV pulsing once per second The high intensity pulse rate warning light should flash once with each fence pulse If the pulse rate warning light double pulses the energizer is working harder than 95 of its design capacity The higher the fence voltage is set or the larger the fence or more foliage touching the fence the greater the energizer effort required to energize the f...

Page 12: ...ned off by navigating back to the NEMTEK item and pressing the button The menu item PIN selected through the long press of the button allows the setting of a user pin This user pin is used in locking an energizer To change a digit in the pin cycle through to the digit by repeatedly pressing and releasing the button The flashing cursor beneath the digit to be edited will move to the right with each...

Page 13: ...p sound is heard slowly move the remote over the face of the energizer in the vicinity of the Nemtek logo On hearing a beep long or short you can move the remote away from the energizer and a new menu will appear on the display of the remote through which you can start navigating The energizer menu Menu Item Lower limit Upper Limit Factory default Description Supply Battery supply voltage informat...

Page 14: ... capacity reached warning set the WARN AT value to 95 Thus when the high intensity warning light begins to double flash it is known that the voltage on the fence is about to or has already dropped bellow the required set voltage V MIN information reported is the lowest fence voltage detected since the energizer was last read using a remote MAX information is the maximum energizer effort or capacit...

Page 15: ...ow voltage wiring Always use ferrules or line clamps to connect two high voltage wires together Avoid using dissimilar materials for connections like copper on steel The fence must be earthed properly with three earth electrodes close to the energizer The distance between the fence earth electrode and any other earth systems shall be not less than 2m for a security fence installation Typically a s...

Page 16: ... barrier Electric animal fence An electric fence used to contain animals within or exclude animals from a particular area Electric Security Fence A fence used for security purposes which comprises an electric fence and a physical barrier electrically isolated from the electric fence Public Access Area Any area where persons are protected from inadvertent contact with pulsed conductors by a physica...

Page 17: ...ductors or non insulated connecting leads supplied from different energizers This spacing may be less where conductors or connecting leads are covered by insulating sleeving or consist of insulated cables rated to at least 10kV This requirement need not apply where the separately energized conductors are separated by a physical barrier which does not have any openings greater than 50mm A vertical ...

Page 18: ...ply wiring shall not be installed in the same conduit as signaling leads associated with the electric fence installation Where an electric fence passes below bare power line conductors the highest metallic element shall be effectively earthed for a distance of not less than 5m on either side of the crossing point Crossings with overhead power lines shall be avoided wherever possible If such a cros...

Page 19: ...19 AGRI xJ Document revision history DOCUMENT REVISION HISTORY Rev 0 0 17 September 2010 First release ...

Reviews: