background image

 

 

 

Page | 7 

 

P: 419.542.7751    F: 419.542.6690   800.782.761   nemcofoodequip.com 

 

 

 

49232A 

Temperature Control Mode

 

If you purchased the optional Temperature Probe, you can use this unit in Temperature 

Control Mode.   

1.

 

Plug the temperature probe into the jack on the back of the unit.  Tighten the 
screw-ring to secure the probe in the connector. 

2.

 

Place the probe in the pot.  Make sure the probe is in the liquid, but not touching 
the bottom of the pot. 

3.

 

With the unit in the Ready state, press the ‘MODE’ button.  The display will show 

‘000F’.

 

4.

 

Press the ‘Start/Stop’ button.  The unit will turn on, and the display will show 

‘100F’.

 

5.

 

Use the ‘ʌ’ 

up 

and ‘v’ down buttons to set the desired temperature in degrees 

Fahrenheit. 

6.

 

The display will alternate between the actual temperature and your set point. 

7.

 

When the food temperature reaches the set point, the display will lock on the 
actual temperature.  The unit will cycle as necessary to maintain the set point 
temperature. 

8.

 

 

Timer Mode

 

The timer function allows you to set a timer from 1 second, up to 719 minutes.  The 

timer resets to 719 minutes every time the power is turned off/on.   The timer always 

runs in the background, so if the unit runs continuously for 12 hours (719 minutes), the 

timer will run out and the unit will turn off.   To reset, turn the power off/on, or 

manually set the timer. 

Setting the Timer 
 

 

With the unit powered on and in the Ready state 

(display shows a steady ‘00’), 

press the ‘TMR’ button.  The display will show ‘

07

19’

.   

 

To change the timer setting, press the 

‘MIN/SEC’ button.  The display will flash 

‘719’.

 

 

Use the ‘ʌ’ up and ‘v’ down buttons to adjust the nu

mber of minutes.  Pressing 

the ‘v’ button will reduce the number of minutes.  If you press the ‘ʌ’ button

 past 

719, 

the display will go to ’00.59’ or 59 seconds.  Keep pressing the ‘ʌ’ button to 

increase the minutes. 

Summary of Contents for 9130A

Page 1: ...nce and repairs be conducted by authorized service agents using genuine Nemco replacement parts Nemco is not responsible for the damages caused by unauthorized service agents or parts The information...

Page 2: ...m 49232A Table of Contents Important Safety Instructions 3 Control Features 4 Power Settings Cooking Guide 6 Temperature Control Mode 7 Timer Mode 7 Setting the Timer 7 Cleaning the Induction Range 8...

Page 3: ...ed cord or plug broken or cracked glass surface if it is not working properly or if it has been damaged or dropped 10 This appliance should be serviced only by qualified service personnel Contact Nemc...

Page 4: ...me cooking by placing the pan on the cooktop and pressing the START STOP button If the temperature of the cooktop reaches 260o C or 500o F the unit turns off automatically and displays an error code T...

Page 5: ...01 to 10 for cooking powers Below power level 01 there are 7 holding or warming settings H1 thru H7 that can be used to hold food at a constant temperature 8 While cooking or warming press the START S...

Page 6: ...tings of 8 9 or 10 2 Boil Water Boil water on high heat settings of 9 or 10 then reduce to level 5 or 6 to maintain a hard boil Reduce to 3 or 4 for a slow boil 3 Pan Fry Pan fry on medium to high hea...

Page 7: ...mperature reaches the set point the display will lock on the actual temperature The unit will cycle as necessary to maintain the set point temperature 8 Timer Mode The timer function allows you to set...

Page 8: ...ternating the display While the unit is heating the timer display decimal points will flash Once the timer counts down to zero pressing the Start Stop button will restart the cycle at the time that yo...

Page 9: ...be flat within about 1 8 of an inch For best results the maximum bottom diameter of the pan should not exceed 10 25 inches Materials that will NOT work with induction ranges include glass ceramics ea...

Page 10: ...erify that the outlet voltage is correct and within limits Unplug the unit Plug it back in If the error continues contact customer service E4 Main Heat Sink Over Temp Check to verify that the fans are...

Page 11: ...Bead Temp Probe Harness Glass Overlay Air Filter FOOT 4 PER 9130A 48856A 48864 48872A 48889 48878 48881 48884 2 48918 48921 48923 45824 9130A C 48856A 48864 48872A 48889 48878 48881 48884 2 48918 489...

Page 12: ...ized repair voids this warranty For purposes of this warranty the phrase normal use shall mean the use of the product in connection with food in accordance with the product manual accompanying the pro...

Page 13: ...Page 13 P 419 542 7751 F 419 542 6690 800 782 761 nemcofoodequip com 49232A 301 Meuse Argonne Hicksville OH 43526 www nemcofoodequip com...

Reviews: