8.
Maintenance
8.1
Care and cleaning
The stud welding system requires no special care.
See the operating instructions specific to the units for the necessary cleaning work
to the gun and if need be to the feeder.
The cleaning work specified below is necessary for the Nelweld N1500i unit. In this
connection, pay attention to the following:
Warning!
Prior to commencing any cleaning work the welding unit must be
switched off, disconnected from the mains and secured against
restart!
Perform preventive maintenance procedures at least once every six months. It is
good practice to keep a preventive maintenance record; a record tag attached to the
machine works best.
•
Neither aggressive or alcoholic agents nor combustible liquids may be used for
the cleaning work.
•
The unit casing of the Nelweld N1500i must be wiped down with a dry cloth. Type
plate and safety advice must be very legible.
•
The front plate of the Nelweld N1500i must be cleaned with a fat-dissolving
cleansing agent. The LED display elements must be recognisable.
•
The electrical connecting cables must be cleaned with a dry cloth. Scorching or
mechanical faults can thus be easily detected.
•
Cleaning inside the unit is required in keeping with the operating conditions and
the degree of soiling.
•
Impurities inside the welding unit, such as metallic dust or con- ductive swarf,
must be wiped out or vacuumed off.