TROUBLESHOOTING/SERVICE
SYMPTOM
POSSIBLE CAUSE
SOLUTION
No output to zone, pump, master
• AC disconnected
• Check AC source, if AC is not
valve or no AC indicator lit
detected by the controller, the no
AC indicator will be lit
No AC and blank display
• No battery or dead battery
• Replace battery and press reset
LCD is blank
• No AC and no battery
• Install battery to regain use of
display, check AC to ensure
output to field
“M-X” appears on the LCD when
• MODE dial is in program position
• Position the MODE dial in the
trying to run a zone manually
AUTO position to run a zone
manually
“C-X” appears on the LCD when
• MODE dial is in program position
• Position the MODE dial in the
trying to CYCLE a program
AUTO position to cycle a program
P with a zone number appears
• Wires not connected or short in
• Check field wiring, check
on LCD
wires or solenoid
solenoid, replace solenoid
• More than 2 solenoids connected
to a zone
• TVS damaged due to lightning
• Remove zone wire if Pxxz still
or improper grounding
shows when run manually or
automatically, unit needs
service/replacement
ALL 24HR flashing on LCD
• Greater than 24 hours of run time • Check zone run times and
programmed
% WATER BUDGET
Rain Sensor symbol on
• Rain sensor is activated or if no
• Check to see if jumper is installed
rain sensor installed, the jumper
if there is no rain sensor
is missing
Controller not responding to any
• Unit needs reset
• Screwdriver across pads
dial/key press
marked Reset
No output to a single zone
• Wiring issues or bad solenoid
• Check wiring and/or solenoid
No output to any zone
• Broken on disconnected common • Check common wire
• RS wired into common wire is
open or disconnected
27
Summary of Contents for EZ Pro Jr
Page 1: ...EZ PRO Jr Instructions Zone Chart 1 2 3 4 5 6 7 8 9 10 11 12 Rev 5 03...
Page 29: ...Mode d emploi du EZ PRO Jr Graphique des Zones 1 2 3 4 5 6 7 8 9 10 11 12 976 60342 Rev 5 03...
Page 57: ...Instrucciones para el EZ PRO Jr Gr fico de Zona 1 2 3 4 5 6 7 8 9 10 11 12 976 60341 Rev 5 03...
Page 85: ...Instru es do EZ PRO Jr Plano das reas 1 2 3 4 5 6 7 8 9 10 11 12 976 60343 Rev 5 03...
Page 113: ...Istruzioni EZ PRO Jr Tabella delle zone 1 2 3 4 5 6 7 8 9 10 11 12 976 60344 Rev 5 03...
Page 141: ...EZ PRO Jr Anleitung Zone Chart 1 2 3 4 5 6 7 8 9 10 11 12 Rev 4 03...