9
IMO-218 EN - Issue 8/2020
3.5 SETTING
All actuators are factory set to 0 and 90 degrees. Even minor
adjustments of the stroke adjustment screws (5A and 5B) will result
in over travel or incomplete travel of the pinion.
Loose nut #13 and rotate screw 5A in counter clock wise direction
(CCW) to set over travel (close)
Loose nut #13 and rotate screw 5A in clock wise direction (CW) to
set under travel (close).
Loose nut #13 and rotate screw 5B in counter clock wise direction
(CCW) to set over travel (open).
Loose nut #13 and rotate screw 5B in clock wise direction (CW) to
set under travel (open).
Pie chart below shows the exact degree of pinion travel.
Table below shows required revolution of the bolts for 1° travel of
pinion for each actuator.
Actuator
size
Revolution of bolts
for 1° travel of pinion
RNP 40
Half quarter turn
RNP 50
Half quarter turn
RNP 63
Half quarter turn
RNP 80
Quarter turn
RNP 90
Quarter turn
RNP 100
Quarter turn
RNP 110
Quarter turn
RNP 125
Quarter turn
RNP 150
Quarter turn
RNP 175
Quarter turn
RNP 200
Quarter turn
RNP 250
Quarter turn
RNP 300
Quarter turn
RNP 350
Quarter turn
4. MAINTENANCE
4.1 MAINTENANCE GENERAL
CAUTION:
OBSERVE THE SAFETY PRECAUTIONS MENTIONED IN
SECTION 1.7 BEFORE MAINTENANCE!
Although Neles actuators are designed to work under severe
conditions, proper preventative maintenance Can significantly help
to prevent unplanned downtime and in real terms reduce the total
cost of ownership. Neles recommends inspecting the actuators at
least every five (5) years. The inspection and maintenance interval
depend on the actual application and process condition. The
inspection and maintenance intervals can be specified together with
your local Neles experts.
During this periodic inspection the parts detailed in the Spare Part
Set should be replaced. Time in storage should be included in the
inspection interval.
If maintenance assistance is required, please contact your local
Neles office. The part numbers in parentheses () in the text refer
to the exploded view and to the parts list in Section 8, unless
otherwise stated.