en
Basic operation
8
7.10 Sensor sensitivity
1
In automatic mode, a sensor in the appliance detects
the intensity of the cooking odours and roasting
odours. Depending on the setting of the sensor sensit-
ivity, the optimum fan setting is automatically switched
on.
If the sensor control reacts too weakly or too strongly,
you can change the setting for the sensor sensitivity.
¡
Default setting: Fan setting 3
¡
Lowest setting: Fan setting 1
¡
Highest setting: Fan setting 5
7.11 Setting the sensor sensitivity
1
Requirement:
The appliance is switched on.
1.
Press and hold and for approx. 3 seconds.
2.
Press or to change the setting.
3.
Press to save the setting.
Or wait approx. five seconds until the setting is
saved automatically.
a
A signal tone sounds as soon as the selected set-
ting is saved.
7.12 Saturation indicator
If the grease filters or odour filters are saturated, cor-
responding symbols flash after the appliance is
switched off.
Note:
You can set the saturation indicator in the Home
Connect app depending on the filter used.
Clean the saturated grease filters and, in doing so, ob-
serve the cleaning instructions in these instructions.
Change the saturated odour filters and observe the in-
structions in the accompanying instructions.
If odour filters can be regenerated, follow the instruc-
tions in the accompanying instructions.
7.13 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:
The appliance is switched on.
1.
Press and hold and for approx. 3 seconds.
‒
To set circulating-air mode (Clean Air Standard
circulating-air set or Clean Air Plus circulating-air
set), press and hold / until LED 2 lights up in
the LED display.
‒
To set circulating-air mode (regenerable filter),
press / until LED 3 lights up in the LED dis-
play.
‒
To convert the electronic control back to opera-
tion without the air recirculation filter, press /
until LED 1 lights up on the LED display.
2.
Press to save the setting.
Or wait approx. five seconds until the setting is
saved automatically.
a
A signal tone sounds as soon as the selected set-
ting is saved.
7.14 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡
After switching off the appliance, the upper two LEDs
for the grease filter's saturation indicator and/or the
lower two LEDs for the odour filter's saturation indic-
ator flash in the left hand control panel.
¡
A signal sounds repeatedly.
▶
Press .
a
The saturation indicator is reset.
7.15 Switching on Ambient Light
1
Notes
¡
You can switch the Ambient Light on and off in the
Home Connect app.
¡
Additional colours are available in the Home Con-
nect app.
Requirement:
Fan setting 1 is switched on.
▶
Press .
a
The Ambient Light remains switched on.
a
The ventilation system switches off.
a
The glass panel remains at the top.
7.16 Switching on Guided Air
With the Guided Air function, the cooking vapour is
routed in such a way that it can be optimally collected
from the appliance and removed. The extraction of the
cooking vapour is improved on front cooking zones in
particular.
Note:
This function is switched off by default.
▶
Press .
7.17 Switching off Guided Air
▶
Press .
1
Depending on the appliance specifications
Summary of Contents for I98WMM1Y7B