NEFF DIKP951S Instructions For Installation And Use Manual Download Page 23

 General information  

en

23

:

Warning

Hazard due to magnetism!

Permanent magnets are inserted in the 

appliance front. They may affect electronic 

implants, e.g. heart pacemakers or insulin 

pumps. Wearers of electronic implants must 

stay at least 10 cm away from the appliance 

front.

:

Warning

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

Risk of electric shock!

It must always be possible to disconnect 

the appliance from the electricity supply. 

The appliance must only be connected to a 

protective contact socket that has been 

correctly installed. If the plug is no longer 

accessible once the appliance has been 

installed, or a fixed connection is required, 

the installation must have an all-pole 

isolating switch with a contact gap of at 

least 3 mm. Only an electrician may install 

the fixed connection. We recommend 

installing a residual-current circuit breaker 

(RCCB) in the appliance's power supply 

circuit.

:

Warning

Risk of electric shock!

Incorrect repairs are dangerous. Repairs may 

only be carried out and damaged power 

cables replaced by one of our trained after-

sales technicians. If the appliance is defective, 

unplug the appliance from the mains or switch 

off the circuit breaker in the fuse box. Contact 

the after-sales service.

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

K

General information

General i

nformatio

n

Checking the wall

The wall must be level, vertical and adequately load-

bearing.

The depth of the bore holes must be the same 

length as the screws. The wall plugs must have a 

secure grip.

The enclosed screws and wall plugs are suitable for 

solid brickwork. Suitable fasteners must be used for 

other structures (e.g. plasterboard, porous concrete, 

poroton bricks).

The maximum weight of the extractor hood is 

40 kg

.

Electrical connection

:

Warning

Risk of electric shock!

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

The required connection information can be found on 

the rating plate on the top of the appliance.

Length of the cable: approx. 1.30 m

This appliance complies with the EC interference 

suppression regulations.

:

Warning

Risk of electric shock!

It must always be possible to disconnect the appliance 

from the electricity supply. The appliance must only be 

connected to a protective contact socket that has been 

correctly installed. If the plug is no longer accessible 

once the appliance has been installed, or a fixed 

connection is required, the installation must have an all-

pole isolating switch with a contact gap of at least 

3 mm. Only an electrician may install the fixed 

connection. We recommend installing a residual-current 

circuit breaker (RCCB) in the appliance's power supply 

circuit.

Summary of Contents for DIKP951S

Page 1: ...en Instructions for installation and use Extractor hood...

Page 2: ...cation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufactu...

Page 3: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Page 4: ...the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the a...

Page 5: ...des Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain h...

Page 6: ...ns for approximately 5 minutes per hour at fan setting 1 Switching off Touch the 3 symbol This ends the AirFresh function Intensive setting You can use the intensive setting if there is a large build...

Page 7: ...troller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filte...

Page 8: ...ymbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touc...

Page 9: ...g over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hol...

Page 10: ...ol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset...

Page 11: ...he Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that cannot be regenerated Take your finger off the Q symbol This will switch the electronic controller over...

Page 12: ...symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on To...

Page 13: ...ing over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched on Touch and ho...

Page 14: ...fan setting 1 The fan will run at fan setting 1 After approximately 10 minutes the fan will switch itself off automatically Switching off Touch the symbol to select a different fan setting This immedi...

Page 15: ...r activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal filter Metal grease filter and activat...

Page 16: ...ll purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 O...

Page 17: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher...

Page 18: ...appliance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit b...

Page 19: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Page 20: ...be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mo...

Page 21: ...ion Damage to the appliance The surfaces of the appliance are sensitive Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For t...

Page 22: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Page 23: ...ing Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information Generalinformation Checking the wall The wall must be le...

Page 24: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hoo...

Page 25: ...g without a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in ful...

Page 26: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of...

Page 27: ...6...

Page 28: ...www neff international com 9001159981 9001159981 961005 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Reviews: