Hob-based hood control

 en

9

¡

In networked standby mode, the appliance requires

a maximum of 2 W.

9.1 Setting up Home Connect

Requirements

¡

The appliance is switched off.

¡

You have a mobile device with a current version of

the iOS or Android operating system, e.g. a smart-

phone.

¡

The mobile device and the appliance are within

range of your home network's Wi-Fi signal.

1.

Download the Home Connect app.

2.

Open the Home Connect app and scan the follow-

ing QR code.

3.

Follow the instructions in the Home Connect app.

9.2 Resetting the connection

To reset the saved connections to the home net-

work and to Home Connect, press   twice.

9.3 Software update

Your appliance's software can be updated using the

software update function, e.g. for the purposes of op-

timisation, troubleshooting or security updates.

To do this, you must be a registered Home Con-

nect user, have installed the app on your mobile device

and be connected to the Home Connect server.

As soon as a software update is available, you will be

informed via the Home Connect app and will be able to

start the software update via the app. Once the update

has been successfully downloaded, you can start in-

stalling it via the Home Connect app if you are in your

home network (Wi-Fi). The Home Connect app informs

you once installation is successful.

Notes

¡

The software update consists of two steps.

The first step is the download.

The second step is the installation on your appli-

ance.

¡

You can continue to use your appliance as normal

while updates are downloading. Depending on your

personal settings in the app, software updates can

also be set to download automatically.

¡

Installation takes a few minutes. You cannot use

your appliance during installation.

¡

We recommend that you install security updates as

soon as possible.

9.4 Remote diagnostics

Customer Service can use Remote Diagnostics to ac-

cess your appliance if you contact them, have your ap-

pliance connected to the Home Connect server and if

Remote Diagnostics is available in the country in which

you are using the appliance.

Tip: 

For further information and details about the avail-

ability of Remote Diagnostics in your country, please

visit the service/support section of your local website:

www.home-connect.com.

9.5 Data protection

Please see the information on data protection.

The first time your appliance is registered on a home

network connected to the Internet, your appliance will

transmit the following types of data to the

Home Connect server (initial registration):

¡

Unique appliance identification (consisting of appli-

ance codes as well as the MAC address of the Wi-Fi

communication module installed).

¡

Security certificate of the Wi-Fi communication mod-

ule (to ensure a secure data connection).

¡

The current software and hardware version of your

appliance.

¡

Status of any previous reset to factory settings.

This initial registration prepares the Home Connect

functions for use and is only required when you want to

use the Home Connect functions for the first time.

Note: 

Please note that the Home Connect functions

can only be utilised with the Home Connect app. In-

formation on data protection can be retrieved in the

Home Connect app.

Hob-ba s e d h ood c on trol

10  Hob-based hood control

You can connect your appliance to a suitable hob and,

in this way, control the functions of your appliance via

the hob.

If the hob and the extractor hood are Home Connect-

compatible, connect the appliances in the Home Con-

nect app. To do this, connect the two appliances to

Home Connect and follow the instructions in the app.

Notes

¡

Please note the safety precautions in the instruction

manual for your appliance and ensure that they are

also observed when operating the appliance via the

hob-based hood control.

¡

Operating your appliance always takes priority. It is

not possible to use the hob-based hood control dur-

ing this time.

¡

You can only connect to the extractor hood via the

Home Connect app. Other connection routes are no

longer supported.

Summary of Contents for D98IPT2S0B

Page 1: ...Extractor hood User manual and installation instructions D98IPT2S0 D98IPT2S0B D98IPT2Y5...

Page 2: ...cooking vapour in private households and in enclosed spaces in a domestic environment up to an altitude of max 4000 m above sea level 1 3 Restriction on user group This appliance may be used by childr...

Page 3: ...ot let children play with small parts WARNING Risk of poisoning Risk of poisoning from flue gases being drawn back in Room air dependent heat pro ducing appliances e g gas oil wood or coal operated he...

Page 4: ...isk of electric shock If the appliance or the power cord is dam aged this is dangerous Never operate a damaged appliance Never pull on the power cord to unplug the appliance Always unplug the applianc...

Page 5: ...n speed in good time The odours are distributed around the room less Switch off the lighting if it is no longer required When the lighting is switched off it does not con sume any energy Clean or repl...

Page 6: ...the filter saturation indicator Switching the appliance on or off Home Connect Selecting the favourites function Switching on fan setting 1 Switching on fan setting 2 Switching on fan setting 3 Switch...

Page 7: ...pending on the setting of the sensor sensit ivity the optimum fan setting is automatically switched on You can change the sensor sensitivity setting in the Home Connect app Factory setting 3 Lowest se...

Page 8: ...and is used to dry the odour filter after the cooking process 8 7 Interval ventilation In order to regularly ventilate your kitchen you can use the interval ventilation With interval ventilation the v...

Page 9: ...act them have your ap pliance connected to the Home Connect server and if Remote Diagnostics is available in the country in which you are using the appliance Tip For further information and details ab...

Page 10: ...lectric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance WARNING Risk of burns The appliance becom...

Page 11: ...grease filter Page 10 1 Observe the information regarding the cleaning agents Cleaning products Page 10 2 Place the grease filters loosely into the dishwasher Do not clean heavily soiled grease filte...

Page 12: ...y a It may take a few minutes until all of the functions are available General malfunctions occur A software update may be required Update the software Software update Page 9 Di s pos al 13 Disposal 1...

Page 13: ...Plus air recircu lation set Z51BII1X6 Clean Air Plus recircula tion kit flue free angled extractor hood Z51BIV1X6 Accessories Order number Long Life recirculation kit flue free angled ex tractor hood...

Page 14: ...sger te GmbH Carl Wery Str 34 81739 Munich Germany The source code will be made available to you on re quest Please send your request to ossrequest bshg com or BSH Hausger te GmbH Carl Wery Str 34 817...

Page 15: ...n instructions en 15 19 2 Included with the appliance After unpacking all parts check for any damage in transit and completeness of the delivery 19 3 Dimensions You will find the dimensions of the app...

Page 16: ...eric pressure Toxic gases from the chimney or the extrac tion shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air...

Page 17: ...tall unit an upper cabinet or a wall The dis tance between the appliance and the tall cabinet an upper cabinet or the wall must be at least 50 mm WARNING Risk of injury Components inside the appliance...

Page 18: ...for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch must be integrated into the permanent electrical in stallatio...

Page 19: ...n the installation situation Page 18 2 Ensure that there are no electrical wires gas pipes or water pipes in the area where holes are to be drilled 3 Cover the hob to prevent damage 4 Determine the po...

Page 20: ...ight of the appliance from above using a screw driver 5 Secure the appliance from above using 2 nuts 6 Note Do not knock the gas pressure dampers against the painted inner frame Clip the gas pressure...

Page 21: ...onnection exhaust pipe 150 mm diameter 1 Secure the exhaust pipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Installing the flue duct WARNING Risk...

Page 22: ...e design profiles observe the enclosed in structions for the accessory Removing the appliance Note The design profiles are not hand grip elements Do not lift the appliance by the design profiles 1 Rem...

Page 23: ......

Page 24: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001809512 9001809512 031019 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...

Reviews: