background image

en

    Home Connect

10

o

Home Connect

Home Connect

This appliance can be networked and also controlled 

using a mobile device. 
If the appliance is not connected to your home network, 

it will function as an extractor hood with no network 

connection and can still be operated via the display.
The availability of the Home Connect function depends 

on the availability of Home Connect services in your 

country. Home Connect services are not available in 

every country. You can find more information on this at 

www.home-connect.com.

Notes

Ensure that you follow the safety instructions in this 

instruction manual and that you comply with these 

even when you are away from home and are 

operating the appliance via the Home Connect app. 

You must also follow the instructions in the Home 

Connect app.

Operating the appliance directly from the appliance 

always takes priority. It is not possible to operate the 

appliance using the Home Connect app during this 

time.

Setting up

To implement settings via Home Connect, you must 

have installed and set up the Home Connect app on 

your mobile device.
Refer to the Home Connect documents supplied for 

more information.
The app will guide you through the entire registration 

process. Follow the steps specified by the app to 

implement the settings.
The app must be open in order to perform the set-up 

process.

Notes

In networked standby mode, your appliance requires 

a maximum of 2 W.

If you need your device's MAC address to connect to 

your home network, you can find this next to the 

rating plate inside the appliance (you will need to 

remove the filter to see it).

Automatic registration in the home network

Notes

You need a router that has WPS functionality.

You need to be able to access your router. If you do 

not have this, follow the steps for "Manually logging 

into your home network".

The extractor hood cannot be switched on during the 

connection process. You can cancel the process at 

any time by pressing the 

#

 symbol.

To connect the extractor hood to your home 

network, the extractor hood must be switched on.

1.

Press and hold the 

#

 and 

˜

 symbols at the same 

time until the 

D

 and 

Ù

 indicators start flashing.

2.

Tap the + symbol to start automatic login to your 

home network. 

D

 and 

 will flash.

3.

Press the WPS button on the router within the next 

2 minutes.

If the extractor hood has successfully connected, it 

will automatically connect to the Home Connect app. 

D

 and 

 will flash.

Note: 

If the extractor hood has been unable to 

connect, it will automatically allow you to manually 

connect to your home network. 

D

 and 

ƒ

 will flash. 

Log the appliance into your home network manually 

or tap - to try logging in automatically again.

4.

On your mobile device, follow the instructions for 

automatic network login.

The login process is complete when the 

D

 indicator 

stops flashing on the control panel and remains 

continuously lit.

Manual registration in the home network

Notes

The extractor hood cannot be switched on during the 

connection process. You can cancel the process at 

any time by pressing the 

#

 symbol.

To connect the extractor hood to your home 

network, the extractor hood must be switched on.

1.

Press and hold the 

#

 and 

˜

 symbols at the same 

time until the 

D

 and 

Ù

 indicators start flashing.

2.

Tap the + symbol twice to manually log into your 

home network. 

D

 and 

ƒ

 will flash.

3.

Use the "Home Connect" SSID and the "Home 

Connect" key to log your mobile device into the 

extractor hood network.

If the extractor hood has successfully connected, it 

will automatically connect to the Home Connect app. 

D

 and 

 will flash.

4.

On your mobile device, follow the instructions for 

manually logging into your network.

The login process is complete when the 

D

 indicator 

stops flashing on the control panel and remains 

continuously lit.

Summary of Contents for D96BMV5N5B

Page 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Page 2: ......

Page 3: ...ts installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during opera...

Page 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Page 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Page 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Page 7: ...nction will remain active even after the fan is switched off Touch the Q symbol Switching off Touch the Q symbol AirFresh function Switching on Touch the 3 symbol 3 will be shown on the display panel...

Page 8: ...activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal filter Metal grease filter and activated...

Page 9: ...cting the appliance reset all existing connections to the WiFi or other appliances If your extractor hood is connected directly to the hob it cannot be connected to your WiFi as well and you will not...

Page 10: ...the steps for Manually logging into your home network The extractor hood cannot be switched on during the connection process You can cancel the process at any time by pressing the symbol To connect t...

Page 11: ...is available in your country Note For more information and to check whether the remote diagnostics service is available in your country please visit the Help Support area of the Home Connect website f...

Page 12: ...Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grea...

Page 13: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher...

Page 14: ...tal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Ple...

Page 15: ...regenerated Z5270X0 Z5170X1 Easy change filter for CleanAir recirculation mod ule can be regenerated Z50XXP0X0 CleanAir air recirculation module can be inte grated Z51FXI0X5 RegeneratableCleanAirreci...

Page 16: ...that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond...

Page 17: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Page 18: ...flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating...

Page 19: ...ck It must always be possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket that has been correctly installed The mains pl...

Page 20: ...2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in t...

Page 21: ...e air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appr...

Page 22: ...6...

Page 23: ...6...

Page 24: ...9001359245 9001359245 en...

Reviews: