background image

en

    Operating the appliance

6

1

Operating the appliance

Operating the appliance

These instructions apply to several appliance variants. 

It is possible that individual features are described 

which do not apply to your appliance.

Note: 

Switch on the extractor hood when you start 

cooking and switch it off again several minutes after you 

have finished cooking. This is the most effective way of 

removing the kitchen fumes.

Control panel

Setting the fan

Switching on

Touch the 

#

 symbol.

The fan starts at fan setting 2.

Selecting the fan setting

Touch symbol 1, 2 or 3 to set a different fan setting.

Switching off

Touch the 

#

 symbol.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.

Switching on

Touch the 

˜

 symbol.

Note: 

After approx. 6 minutes, the extractor hood 

automatically switches back to fan setting 3.

Switching off

If you want to end intensive mode before the preset 

time expires, touch the 

˜

 symbol.

Intermediate position for the glass front

On some appliances, the glass front can be adjusted to 

an intermediate position. The intermediate position can 

be used for eliminating particularly strong cooking 

smells and large amounts of steam. 
Take hold of the glass front in the centre and open it 

carefully.

Lighting

The lighting can be switched on and off independently 

of the fan.
Touch the 

6

 symbol.

Symbol

Explanation

#

Fan on/off

1-3

Fan settings

˜

Intensive mode

6

Light on/off/dimming

Summary of Contents for D95FRM1S0B

Page 1: ...en Instructions for installation and use Extractor hood...

Page 2: ...mestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is ca...

Page 3: ...not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes o...

Page 4: ...d by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk...

Page 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain he...

Page 6: ...ol Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol Note After approx 6 minutes the extractor hood automatical...

Page 7: ...ve limescale Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removin...

Page 8: ...inse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher T...

Page 9: ...iance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an...

Page 10: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Page 11: ...to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation...

Page 12: ...ppliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least...

Page 13: ...l vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cann...

Page 14: ...KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs m...

Page 15: ...r hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor h...

Page 16: ...out a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP...

Page 17: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of...

Page 18: ...6...

Page 19: ...6...

Page 20: ...www neff international com 9001227065 9001227065 970606 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Reviews: