background image

Installation instructions

 en

11

 12.4 Secure installation

Follow these safety instructions when in-
stalling the appliance.

WARNING ‒ Risk of poisoning!

Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the flue or the extraction
shaft are sucked back into the living space. 

Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room-air-dependent heat-producing appli-
ance is being operated.

It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
drop more than 4 Pa (0.04 mbar) below at-
mospheric pressure. This can be achieved
whenever the air needed for combustion is
able to enter through openings that cannot
be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by
other technical means. An incoming/ex-
haust air wall box alone does not ensure
compliance with the limit.

In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.

Unrestricted operation is possible if the ap-
pliance is operated exclusively in circulat-
ing-air mode.

Summary of Contents for D92 Series

Page 1: ...Extractor hood en User manual and installation instructions 2 D92 D62 D94 D64...

Page 2: ...2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sens...

Page 3: ...use s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING R...

Page 4: ...correct cleaning damages the surfaces Follow the cleaning instructions Do not use harsh or abrasive detergents Clean stainless steel surfaces in the direction of the finish only Never clean controls w...

Page 5: ...ir back into the room If the exhaust air is to be conveyed into a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conv...

Page 6: ...inium parts in the interior of the appliance may cause explosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commer cial or industrial cleaning agents...

Page 7: ...recommend cleaning the grease filters every two months WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly Requirement The grease filters have...

Page 8: ...Fault Cause and troubleshooting The appliance is not working The mains plug of the power cord is not plugged in Connect the appliance to the power supply The circuit breaker in the fuse box has tripp...

Page 9: ...can be found in the enclosed Customer Service directory or on our website 10 1 Product number E Nr and production number FD You can find the product number E Nr and the pro duction number FD on the ap...

Page 10: ...ge in transit and completeness of the delivery 12 2 Safety clearances Comply with the safety clearances for the appliance For Australia and New Zealand the minimum safety clearance above electrical co...

Page 11: ...space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as a room air dependent heat producing appli ance is being operated It is on...

Page 12: ...appliance and wall or high sided unit must be at least 50 mm The grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flamb ing Do not install th...

Page 13: ...ntact socket that has been correctly installed The mains plug for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch...

Page 14: ...enclosed screws and wall plugs are suitable for use with solid brickwork Use suitable fastening parts for other structures e g plasterboard porous concrete poroton bricks Preparing the wall Note Depen...

Page 15: ...end the piping with an exhaust air pipe dia meter of 150 mm Establishing the exhaust air connection exhaust pipe 150 mm diameter 1 Secure the exhaust pipe to the air pipe connector 2 Establish the con...

Page 16: ...e outer flue duct to protect the surface Place the flue duct sections on the appliance 6 Slide the inner flue duct section upwards and at tach it to the left and right hand sides of the retain ing bra...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Stra e 34 81739 M nchen GERMANY 9001673597 9001673597 020218 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton K...