Fault finding 

 
When errors occur the LED will indicate this. The following will give you a guide to find these errors. 
In the Neets Control – ZULU the LED´s are placed here: 
 

 

 
 
Fault 

 

Solution 

 

SD card missing 

 

 
Control that the SD card is mounted correctly and that the 
uSD card that you are using are formatted with FAT. 

 

Unexpected Error 

 

 
There are properly problems in the project you have 
uploaded. Try e.g. to upload a empty project and see if this 
works or contact Neets or you dealer       

 

Error in serial number 

 

 
Doing the production of the unit, something has gone 
wrong. You need the return the unit to Neets or your 
dealer for replacement/repair.  

 

Unzipping config.zip 

file after power on 

 

 
If you manual have placed a project file on the uSD card 
the system will extract the files needed to run the project. 
After extraction, the system will start to run the project. 

 

Unable to start the 

project 

 

 
This scenario often happens when the uSD card in the unit 
are replaced with a blank uSD card. Alternative there can 
be a problem in the project you have uploaded. Try e.g. to 
upload a empty project and see if this works or contact 
Neets or you dealer       

 

System are in boot 

mode 

 

 
You have put the system in boot mode. This mode allows 
you to communicate with the system using Rx1/Tx1. See 
the section “Switch and LED” on page 7 for details on how 
to get the system into boot mode.  
 

Summary of Contents for Zulu

Page 1: ......

Page 2: ...t information or data in this manual without Neets express written consent CHANGES Neets reserve the right to change the specification and functions of this product without any notice Questions AFTER...

Page 3: ...t 2 Description 3 Connections on units 4 Technical description 5 USB 5 Power output 5 Time Battery RTC 5 RS 232 Port 6 IR RS 232 ports 6 uSD Card 6 Switch and LED 7 I O Ports 7 LAN 7 Onboard relays 8...

Page 4: ...s intelligence behind the scene The box itself is mounted over the ceiling and controlling the requested units through RS 232 IR LAN and I O Description Part number Neets Control ZULU 310 0050 RS 232...

Page 5: ...DC out 2 Fuse to enable screen mode on RELAY 1 and RELAY 2 13 3 RS 232 port 4 RS 232 or IR control out 5 230 VAC power in 6 Relay connectors 7 LED and relay test button 8 Input Output 9 Mini USB 10 S...

Page 6: ...so you do not have to connect 110 230 volt to the unit to program it BUT for long periods of testing testing your program it is recommended to connect 110 230 to the unit since the USB power is not ma...

Page 7: ...PIN 2 Tx uSD Card The uSD Card is used to storage firmware homepage and the settings Under normal operation removal of the uSD Card is not needed If needed you can copy the settings and the firmware d...

Page 8: ...d lock extra relays and so on The ports are not potential free that means you will need external relays if you need to prevent e g ground loops When used as output they are active low when the softwar...

Page 9: ...ector and therefore you must not use the RELAY 1 and RELAY 2 connectors If you do not want to use the Screen connector please remove fuses F402 and F403 SCREEN FUSES 2 5AT Read the section Controlling...

Page 10: ...e time 3 Dry contacts free to be used Cable in out of the box The Neets Control ZULU box comes with rubber globs This allows you to use any cable size you want and the taps inside the box gives you a...

Page 11: ...wrong You need the return the unit to Neets or your dealer for replacement repair Unzipping config zip file after power on If you manual have placed a project file on the uSD card the system will extr...

Page 12: ...LU has a log file which contains information warning and error that the system encounters during run The log file looks like below To give you the best support possible we recommend that you have acce...

Reviews: