8
Activating the batteries
The batteries are activated when attached to the
bracket for the first use.
-
The product must be used with the matching
bracket. The product does not work when used
separately.
Choosing a location
(image
B
&
C
)
For safe use it is recommended to install the product in
areas with a source of combustion where CO and smoke
will move upwards quickly.
The product can be installed in:
•
Every sleeping area.
•
Both ends of a hallway longer than 12 m.
•
Every room where a furnace, a heat source and/or
other burning devices are located.
•
Every room where multiple people spend several
consecutive hours.
•
Install at least one product on each floor of a
multi-level home.
In areas with a source of combustion:
On the ceiling:
•
At least 3 m away from the CO-source.
•
At least 30 cm away from surrounding walls.
•
At a central point in the room.
•
Not in turbulent air (near windows, ceiling fans or air
conditioners).
4
The product can also be installed on a sloped ceiling.
-
Do not install in the tip of a sloping ceiling as
smoke-free air can collect in these areas.
In sleeping areas:
•
Not in turbulent air (near windows, ceiling fans or air
conditioners).
•
Not behind objects (curtains or closets).
Other areas:
•
Not in turbulent air (near windows, ceiling fans or air
conditioners).
•
Not behind objects (curtains or closets).
4
For optimal CO detection install the product at
breathing height.
4
For optimal smoke detection install the product at a
minimal height of 1.80 m.
Do not install the product:
•
in dirty, greasy or dusty areas.
•
in temperatures below 0 ºC.
•
in temperatures above +40 ºC.
•
in turbulent air (near ceiling fans, air conditioners or
open windows).
•
within 3 meters of a high humidity source.
•
within 1.5 meters of kitchen appliances.
•
within 6 m of a furnace or fuel burning heat sources.
•
behind objects like curtains or closets.
•
within 1 m of fluorescent light.
Installing/Mounting the product
(image
D
&
E
)
1. Place
A
4
in the desired location.
Follow steps 2. - 6. for stone/concrete surfaces. Continue
to step 5. for wood surfaces.
2. Use
A
4
to mark the drill locations with a pencil
(70mm in between the two holes).
3. Drill two Ø 5 mm holes.
4. Insert the plugs into the holes.
5. Fasten the mounting bracket with the screws.
6. Turn
A
3
clockwise to attach it to
A
4
.
4
Do not overtighten the screws, this will deform the
bracket.
Testing the product
The product must be tested once a week to ensure
proper operation. Press and hold the test/silence
button.
A
1
blinks red. Hold until the product emits
three long beeps and four long beeps.