background image

Swing Arm SA-G

3.3 Pressure drop diagram

See 

Figure 9

.

4 Installation

WARNING! Risk of personal injury
• The Swing Arm SA-G must be mounted ac-

cording to the installation instructions and
mounted to a wall or to a column with enough
strength to take up the forces caused by the
weight of the arm, permissible extra load,
and the normal use of the arm.

• The band keeping the inner arm and the out-

er arm together, must not be removed until
the installation is finished. The band ensures
the outer arm will not suddenly swing out,
which could cause an accident.

• Work with electric equipment is to be carried

out by a qualified electrician.

4.1 Installation options

See 

Figure 2

 and 

Figure 3

.

• When mounting to a steel or concrete column the

recommendation is to use alt. 1.

• If mounted to a weak wall, it may be necessary to

reinforce the wall and to use long screws going
through the wall according to alt. 2.

• An extra wall bracket with a larger surface area, in

order to distribute the forces over a large area, is
available according to alt. 3.

• Certain arms may be mounted to the roof according

to alt. 4.

4.2 Mounting

Recommended mounting height and suggested loc-
ation of a possible compressed air outlet is shown in

Figure 4

.

• Use four screws, M12, for mounting the bracket.
• For concrete, use M12 para bolts (concrete expan-

sion bolts), 110 mm long, for example Hilti HSA
M12x110/15 and a 12 mm drill. (Alternatively, use
1/2" x 4 1/2" bolts, for example Hilti KB II 12-412 and
drill with 1 /2" drill.) torque, 60 Nm or 45 ft. lb. Thin
spacers may be required if the base is not vertical.

• Mounting of the extra wall bracket on concrete re-

quires longer screws. i.e. Hilti HSA M12 x 180/85
{1/2" x 7"), for the upper two holes.

The stop ring and the tension rod are to be mounted
according to 

Figure 5

.

• Adjust to a certain pulling force with the nut at the

lower end of the tension rod.

WARNING! Risk of personal injury
• Swing Arm SA-G 600 must never be mounted

without the tension rod.

• It is very important that the stop ring is se-

curely fastened.

Swing Arm SA-G 300 and Swing Arm SA-G 450 may
be mounted without the tension rod if mounted to
the roof and a 360° swing range is required. If a 360°
swing range is not required, mounting of the tension
rod is always recommended.
• Make sure the three stop ring screws are locked

with the nuts after they have been screwed in as far
as possible.

The grounding wire is to be mounted according to 

Fig-

ure 6

.

WARNING! Risk of personal injury
Static electricity is often created when
particles pass through a hose at high velocity.
Therefore, the arm must always be grounded
for discharge of static electricity.

1

First cut the vacuum hose to suitable height above
floor level.

2

Peel off the wire plastic coating 40-50 mm in both
ends of the vacuum hose. The coupling is made of
conductive plastics.

3

Turn in the wire at the upper end to make a con-
tact with the arm and with the hose coupling at
the lower end. Twist the coupling counter clock
wise into the hose.

4

Remove any paint or coating for a good contact.
Extend the cable if necessary. The static electri-
city current is very low, a few micro amps. The
mechanical strength of the cable determines the
cable area, 1.5 mm

2

 is recommended.

5

Check that the clip fitted to the inner arm is in con-
tact with the outer arm. See 

Figure 7

.

6

Fit supplied grounding cabe to the stop ring and
link the other end (peeled off) to ground.

7

Ensure the arm can swing within the working area
without tearing off the wire. The compressed air
pipe is usually grounded as well as the building
steel construction.

For arms to be fitted with compressed air, mount the
air hose according to 

Figure 8

 or 

Figure 1

.

• Cut the vacuum hose and the compressed air hose to

a height of 1 -1.5 m above floor level.

NOTE! 
A possible electric outlet should also be located
in level with the hose coupling.

• Check that the arm can swing within desired range

without stretching the hoses. An automatic vacuum
valve TAV 50 is often fitted to the wall bracket and
the air hose is then linked to the valve. Otherwise,

EN

11

Summary of Contents for Swing Arm SA-G 300

Page 1: ...User Manual Arms High Vacuum Swing Arm SA G 300 450 600 Original user manual EN USER MANUAL Translation of original user manual PT MANUAL DO UTILIZADOR SV ANVÄNDARMANUAL 2022 10 28 144349 01 EN PT SV ...

Page 2: ...Swing Arm SA G Trace back information Workspace Main version a68 Checked in 2022 10 28 Skribenta version 5 5 022 ...

Page 3: ...Swing Arm SA G Figures 4 English 9 Português 13 Svenska 17 3 ...

Page 4: ...Swing Arm SA G Figures SA G300 1880 SA G450 SA G600 3250 mm 95 5 522 5 SA G300 SA G450 1120 SA G600 2620 150 1 2 3 4 5 6 7 8 9 10 11 12 12 13 14 1 Alt 1 Alt 2 Alt 3 4x M12 1 2 2 4 ...

Page 5: ...Swing Arm SA G Alt 4 100x100x4 mm 360o SA G 300 SA G 450 2x M12 1 2 4x M12 1 2 15 20 mm 3 Min 1 2 0 5 1 m 2 5 4 5 m 120 mm 205 mm 16 mm 4x 4 5 ...

Page 6: ...Swing Arm SA G 1 2 3 4 5 6 6 ...

Page 7: ...Swing Arm SA G 7 TAV 50 1 1 5 m 8 7 ...

Page 8: ...Swing Arm SA G 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 0 50 100 150 200 250 300 350 400 Pressure drop Pa Air flow m h Pressure drop Swing arms SA G300 SA G450 SA G600 Pa m3 h 9 8 ...

Page 9: ...fication of important information 10 3 Description 10 3 1 Main parts and measurements 10 3 2 Technical data 10 3 3 Pressure drop diagram 11 4 Installation 11 4 1 Installation options 11 4 2 Mounting 11 5 Maintenance 12 6 Accessories 12 7 Spare Parts 12 7 1 Ordering spare parts 12 8 Recycling 12 EN 9 ...

Page 10: ...ury Warnings indicate a potential hazard to the health and safety of personnel and how that hazard may be avoided CAUTION Risk of equipment damage Cautions indicate a potential hazard to the product but not to personnel and how that hazard may be avoided NOTE Notes contain other information that is import ant for personnel 3 Description Swing Arm SA G is an extraction arm for on tool or on torch e...

Page 11: ...mounted without the tension rod It is very important that the stop ring is se curely fastened Swing Arm SA G 300 and Swing Arm SA G 450 may be mounted without the tension rod if mounted to the roof and a 360 swing range is required If a 360 swing range is not required mounting of the tension rod is always recommended Make sure the three stop ring screws are locked with the nuts after they have bee...

Page 12: ... of conductive hose 6 Accessories For weak walls there is an extra wall bracket An automatic vacuum valve type TAV 50 can be fit ted to the standard wall bracket which is fitted with holes for this purpose The valve opens automatically when the arm is used and is otherwise closed A welding wire feeder can be fitted to the arm with a W kit containing a tracking system with trolleys hoses extra wall...

Page 13: ...informações importantes 14 3 Descrição 14 3 1 Peças principais e medições 14 3 2 Dados técnicos 14 3 3 Diagrama de queda de pressão 15 4 Instalação 15 4 1 Opções de instalação 15 4 2 Montagem 15 5 Manutenção 16 6 Acessórios 16 7 Peças sobressalentes 16 7 1 Encomenda de peças sobressalentes 16 8 Reciclagem 16 PT 13 ...

Page 14: ... potencial pa ra a saúde e segurança do pessoal e como esse risco pode ser evitado CUIDADO Risco de danos no equipamento Os avisos indicam um risco em potencial para o produto mas não para o pessoal e como esse risco pode ser evitado NOTA As observações contêm outras informações im portantes para o pessoal 3 Descrição O Swing Arm SA G é um braço de extração para extra ção na ferramenta ou na tocha...

Page 15: ...ridos ou seja Hilti HSA M12 x 180 85 1 2 x 7 para os dois orifícios superiores O anel de paragem e a haste de tensão devem ser montados de acordo com a Figura 5 Ajuste se a uma certa força de tração com a porca na extremidade inferior da haste de tensão ADVERTÊNCIA Risco de ferimentos pes soais O Swing Arm SA G 600 nunca deve ser mon tado sem a haste de tensão É muito importante que o anel de para...

Page 16: ...ço ou na fixação do suporte de parede que possam sig nificar um risco de segurança Verifique as ligações elétricas e de ar comprimido A fuga de ar pode fazer com que a válvula de vácuo au tomática se abra involuntariamente Verifique se há danos desgaste nas mangueiras e cabos Substitua apenas por um tipo original de mangueira condutora 6 Acessórios Para paredes fracas existe um suporte de parede a...

Page 17: ... 1 Klassificering av viktig information 18 3 Beskrivning 18 3 1 Huvuddelar och mått 18 3 2 Tekniska data 18 3 3 Tryckfallsdiagram 19 4 Installation 19 4 1 Installationsalternativ 19 4 2 Montering 19 5 Underhåll 20 6 Tillbehör 20 7 Reservdelar 20 7 1 Beställa reservdelar 20 8 Återvinning 20 SV 17 ...

Page 18: ...Varningar anger en möjlig fara för personalens hälsa och säkerhet samt hur faran kan undvi kas VARSAMHET Risk för skada på utrust ningen Försiktigt betecknar en potentiell risk för pro dukten men innebär inte fara för personal och anger hur risken kan förhindras NOTERA Anmärkningar innehåller annan information som är viktig för medarbetarna 3 Beskrivning Swing Arm SA G är en utsugsarm för utsug på...

Page 19: ... mycket viktigt att klämringen sitter fast ordentligt Swing Arm SA G 300 och Swing Arm SA G 450 kan monteras utan spännstången vid montering på tak och ett svängområde på 360 krävs Om ett svängom råde på 360 inte behövs rekommenderar vi alltid att spännstången monteras Se till att klämringsskruvarna är låsta med muttrarna när de har skruvats in så långt det går Jordningstråden ska monteras enligt ...

Page 20: ...illbehör För svaga väggar finns det ett extra väggfäste En automatisk vakuumventil av typen TAV 50 kan monteras på standardväggfästet som är försett med hål för detta Ventilen öppnas automatiskt när armen används och är annars stängd En svetstrådsmatare kan monteras på armen med ett W kit som innehåller ett skensystem med vagnar slangar extra väggfäste osv Kontakta Nederman för mer information om ...

Page 21: ...www nederman com ...

Reviews: