L-PAK 150/250 Standard
EN
12
6
PLC settings
6.1
Find a parameter and set its value
ESC
OK
NEDERMAN
Hi Vacum Unit
L-PAK Standard
OFF
TimeTo Service
2000 Hours
ESC
OK
Thu 10:45
2018-02-01
ESC
OK
Stop
>
>
Setup
>
Network
>
Diagnos
ti
cs
>
Program
ESC
OK
Set Parameter
Program Name
ESC
OK
H-Meter
>
ZV-Detect
>
SSR_Time
>
DIRTmr
>
OTTmr
Z
WeekTmr
>
Do the following to find a parameter and set its value:
1.
From the PLC status screen, press the down arrow to go to the date and time
screen.
2.
Press ‘Escape’
ESC
to go to the main menu.
3.
Press the down arrow to go to ‘
Program’
. Press ‘OK’
OK
to confirm.
4.
Select
‘Set Parameter’
. Press ‘OK’
OK
to confirm.
5.
Use the up or down arrows
to find the parameter. Press ‘OK’
OK
to confirm.
6.
Use the left and right arrows
to select a value.
7.
Use the up or down arrows
to set the value. Press ‘OK’
OK
to confirm.
8.
Press ‘Escape’
ESC
to go to the main menu.
9.
Press ‘Escape’
ESC
to go to go to the date and time screen.
10.
Press the up arrow to exit.
NOTE!
There are several other input menus on the same level as the date and time screen.
If pressing the down arrow takes the PLC to one of those menus, use the left arrow to
get to the date and time screen.
NOTE!
The blinking cursor shows the current value that can be changed.