FlexFilter EX
18 Troubleshooting
If the trouble shooting guide do not solve the problem, contact your nearest authorised dealer or AB Ph. Neder-
man & Co.. for technical advice.
Error
Possible cause
Solution
Control filter pressure switch
triggered.
Control filter blocked
Change control filter. Check the
main filter for damage.
6 mm hoses to pressure switch are
blocked or damaged.
Clean / replace hose.
The filter in the air hose full.
Replace the filter in the air hose.
Pressure switch/filter not connec-
ted properly.
Check connections.
Pressure switch set too low
Increase setting (Pre-set: 4kPa)
Pressure switch broken
Replace
Control system setting incorrect.
See the instructions for the con-
trol system you use.
No dust collected in Bulk-Bags /
container.
TVFD feed-out not working
See
Filter cleaning not working.
See
Insignificant vacuum/flow en
route to FlexFilter EX.
See Insignificant vacuum/flow
Low vacuum or airflow
Suction source to small
Check capacity of the suction
source.
Suction source malfunction.
Check the suction source.
Deposits / Blockage in pipes en
route to FlexFilter EX.
Clean pipes. Check transport velo-
city.
The duct system not properly di-
mensioned.
Re-dimension the duct system or
add an extra suction source.
Malfunctioning valves in the duct
system.
Check duct system valves.
Filter cleaning malfunctioning or
insufficient
Check function of Solenoid Clean-
ing Valve (SCV)
Filter cleaning not working.
Air pressure or airflow too low
Adjust pressure. Check feed hose
dimension
Solenoid Cleaning Valve not con-
nected properly.
Check valve and air pressure.
Air lines, valve or cylinder blocked.
Clean / replace air lines, valve or
cylinder. Filter incoming com-
pressed air.
EN
45
Summary of Contents for FlexFilter EX Single
Page 8: ...FlexFilter EX Figures B C A D E F G 15 45 15 45 15 45 1 1 m 3 ft R 1 m 3 ft 2 8 ...
Page 12: ...FlexFilter EX D C A E F B G 4 12 ...
Page 13: ...FlexFilter EX 1 2 3 5 6 4 7 9 8 5 13 ...
Page 14: ...FlexFilter EX 4 5 6 3 2 1 6 1 6 4 9 5 8 7 3 2 7 14 ...
Page 15: ...FlexFilter EX 5 s 1 s 30 min A B C USV LSV 8 A E E A B C D G F 9 15 ...
Page 16: ...FlexFilter EX 10 11 12 16 ...
Page 17: ...FlexFilter EX x1 x3 A B 13 17 ...
Page 18: ...FlexFilter EX A A B B 14 18 ...
Page 19: ...FlexFilter EX 15a x1 M12x30 x2 x2 1 2 3 15b 17 A B 16 19 ...
Page 20: ...FlexFilter EX 17a 17b 17c 20 ...
Page 21: ...FlexFilter EX 17d 1 3 2 6 10 bar 4 5 A 18 1 2 3 4 5 19 21 ...
Page 22: ...FlexFilter EX A B 20 22 ...
Page 23: ...FlexFilter EX 1 3 8 13 6 4 9 10 11 5 5 14 7 12 12 14 2 15 15 16 16 21 23 ...
Page 25: ...FlexFilter EX 1 8 A GND 1 7 2 4 5 6 3 23 A B C 24 25 ...
Page 26: ...FlexFilter EX 25 26 ...
Page 27: ...FlexFilter EX A B 26 A B 27 27 ...
Page 387: ...www nederman com ...