background image

VP1007-B / Installation manual

Version 01.000 / November 2020 / EN

5

Livestock Management

2 VP1007-B introduction

The Nedap VP1007-B Transceiver is a reader and input/output controller that is used for feeding, weighing,

milking, heat detection, sorting/routing, identification and so on.

Connectors:

2 Antenna connections, 1 active at the time

FDX sync / HDX sync

HDX and other extra ID options are only available by license. If no license is purchased for the VP1007-

B, these options can be tested for a 24-hour period.

1 CAN channel with 2 connectors

5 Outputs (max 2A)

5 Inputs

1 RS485 / RS232 communication channel

Features:

Identification of tags

Activates and controls e.g. lights, motors, valves, relays

Reads the input for e.g. sensors, switches

Special serial interface (RS485 / RS232) for connecting sensors with serial interface

All currently available Nedap Livestock antennas can be used.

2.1 Extended functionality

The new generation V-packs (V-pack B types) are based on a new transmitter-receiver module with an improved

way of animal identification based on Digital Signal Processing (DSP) technology.
The V-pack B types offer the following new features:

Notch Filter (nF): This option suppresses the signals that are received from long wave transmitters near

Berlin, Frankfurt and Budapest. Especially large antennas such as the Walk Through and Walk Past antennas

are sensitive for this. Noise reduction antennas will not need this notch filter as they already suppress these

long wave transmitter signals.

These new options and the HDX mode must be activated with a license on the VPU (VP8001/VP8002). If the V-

pack is not connected to a VPU, a license for the V-pack must be purchased.

Nedap: If no license is purchased for the VPU or the V-pack, the HDX and/or Notch Filter options can be

tested for a 24-hour period. For more information see the menu overview of the V-pack in the Appendix.

To check if the VP1007 is a B version, a "b" will appear on the display shortly after the VP1007-B is booted.

If a system uses HDX tags, and a VP1007 has to be replaced with a VP1007-B, there are two options:

1. Order a special VP1007-B with HDX license pre-installed on the VP1007-B, or:
2. Order a normal VP1007-B FDX only and add a separate HDX license to the VPU for this VP1007-B.

Summary of Contents for VP1007-B

Page 1: ...Instruction Manual VP1007 B Installation manual Version 01 000 November 2020 EN Original instructions Livestock Management...

Page 2: ...y yourself or reseller and keep a copy for your own records This document can be published in various languages but only the English language version will prevail Nedap N V assumes no responsibility f...

Page 3: ...VP1007 B Installation manual Version 01 000 November 2020 EN 1 Livestock Management VP1007 B...

Page 4: ...3 2 Mount the VP1007 B 7 3 3 Wiring 7 3 3 1 Wiring diagram VP1007 B 9 4 Con guration 11 4 1 Con gure the VP1007 B 11 4 2 Check for rmware updates 12 5 Commissioning 13 5 1 Testing inputs and outputs...

Page 5: ...oderate injury Indicates important information but not hazard related Suggestions and advice to perform certain tasks more easily General safety instructions Warning Always turn off the mains power su...

Page 6: ...oncealed and form no danger for stumbling Caution Take into account the high concentrations of ammonia when installing and maintaining the VP1007 B in pig barns Animal welfare and safety The automated...

Page 7: ...identi cation based on Digital Signal Processing DSP technology The V pack B types offer the following new features Notch Filter nF This option suppresses the signals that are received from long wave...

Page 8: ...ling Install the Velos CAN cable s inside a plastic PVC conduit Do NOT install cables directly to metal ceiling trusses feed lines and power lines Lightning protection It is important to follow closel...

Page 9: ...ing to CISPR 16 1 1 Maximum allowed conducted noise according to EN55032 2015 3 1 3 Tools requirements Screwdriver size 0 4 x 2 5 mm 0 016 x 0 098 in for the LAN connector of the V pack 3 2 Mount the...

Page 10: ...s 4 A I Input Minus for output O and minus input I COMM B Receive data RS 485 A RxD A Send data RS 485 RxD Receive data RS 232 TxD Send data RS 232 Shield RS 485 minus RS 232 ANT 1 Plus core of coax c...

Page 11: ...pack 6 Signal light 3 Switch Wiring colors see Wiring color coding page 28 4 Feed motor 1 Install all wiring according to the VP1007 B wiring diagram An example of a VP1007 B wiring diagram is shown i...

Page 12: ...e to connect the SYNC connectors of two or more VP1007 B transceivers together The cable type is not critical a twin lead or coaxial cable can be used Also the connection is not sensitive for polariza...

Page 13: ...ion If the output LEDs are red flashing there is an output error Go to It dE in the display menu to reset all errors The LED indicators are explained in VP1007 B reader LED indicators page 25 Address...

Page 14: ...d If necessary click on the logic address and change it to a unique number Click Ok to save the change Caution V packs with the same logic address are indicated with a red exclamation mark icon e Cli...

Page 15: ...the test results are shown as a code on the display blinking Code on the display Description motor test results 00 Motor run ok 01 Output already in use 02 No motor current measured 03 No input signal...

Page 16: ...1 for parameter i2 to i5 to test equipment on input I 2 to 5 5 2 Antenna tuning After the rst time power up the antenna tuning must be checked 1 Check the TUNING LED and follow the instructions in th...

Page 17: ...al level using a xed or manually adjustable threshold level When the received signal strength falls below this the receiver is muted When the VP1007 B reads the tag with an RSSI level below this thres...

Page 18: ...e VP1007 B see VP1007 B reader LED indicators page 25 2 Go to HF H1 or H2 AS id and check if the last two digits of the tag ID appear in the display Figure 3 Antenna reading distance adjustment 1 Maxi...

Page 19: ...antenna If there is already a high value when the tag is not in the antenna eld this is an indication that an external source is causing noise see Troubleshooting 2 HDX test a Go to HF AS dH on the d...

Page 20: ...P1007 B reader menu overview page 26 The error code will be displayed Multiple error codes will be displayed one after another with a short gap between each code 2 Press the button to clear the error...

Page 21: ...y caused by error 01 to 08 Check connected device on output 5 Identification performance and disturbance Identi cation performance may be decreased by disturbance caused by variable frequency drives t...

Page 22: ...ibed in this manual Router Networking device that forwards data packets between computer networks RSSI The Received Signal Strength Indication is an indication of the signal strength received by the r...

Page 23: ...onnect other sensors with serial interfaces Cable speci cations Power 1 5 mm 2 0 0023 in 2 90 m 98 yd 2 mm 2 0 0031 in 2 100 m 109 yd CAN bus Velos cable min 0 34 mm 2 0 0005 in 2 twisted pair shielde...

Page 24: ...roduct is responsible for the proper disposal of parts of the product according to local rules and regulations The WEEE symbol in Europe indicates that the relevant electrical product or battery shoul...

Page 25: ...m distance of 3 cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Cet quipement est conforme a CNR 102 lim...

Page 26: ...Cet appareil num rique de Classe B est conforme la norme Canadienne ICES 003 Antennas This device may be used with the following Nedap antennas VP6011 VP6012 VP6030 VP6040 VP6041 VP6042 and VP6050 Ant...

Page 27: ...flashes No rmware present On Address indicated No communication Display Off Communication status OK Green On Power on Blank Off No power On Low power warning lower than 20V Orange Blinking Wrong CAN...

Page 28: ...or low antenna signal TUNING ID Various Red blinking Antenna 2 not connected or low antenna signal 11 2 VP1007 B reader menu overview Use the button to access the menu and to display or change the se...

Page 29: ...t maximum setting 99 possibility to set a lower value Adjust squelch Set FDX squelch Display FDX RSSI Set HDX squelch Display HDX RSSI Identi cation test Antenna options Notch lter VP1007 B only Notch...

Page 30: ...otor control Test output 3 as a motor control Test output 4 as a motor control Test output 5 as a motor control Test output 1 Test output 2 Test output 3 Test output 4 Test output 5 Test input 1 Test...

Page 31: ...ember 2020 EN 29 Livestock Management Color code Wire color VT Violet WH White YW Yellow BK WH Black White BL WH Blue White BN WH Brown White GN WH Green White GY PK Gray Pink OR WH Orange White RD BL...