VP1007-B / Installation manual
Version 01.000 / November 2020 / EN
21
Livestock Management
8 Technical specifications
VP1007-B
Item
Specification
Dimensions (L x W x H)
143 x 120 x 68 mm (5.63 x 4.72 x 2.68 in.) (excluding mounting rail)
Weight
Approx. 360 g (12.7 oz.)
Power supply
The power supply or power adapter must comply with local regulations for a
SELV, limited power (NEC class2, ps2) output (e.g. Nedap VP2001 or Nedap
power adapter part no. 9223126).
Power supply input voltage
25 VDC, ± 20%
Power consumption, minimum
300 mA with the antenna switched on
Power consumption, maximum
4.5 A
Inputs
Reading inputs, five analog (0-35V) and two digital
Suitable for NPN and PNP sensors
Outputs
Max. 2A short-circuiting protected and over temperature protected, I/O
safeguard when total I/O current > 4A
Communication
CAN bus 125 kbit/s
Serial interface
RS-232, RS-485 (to connect other sensors with serial interfaces)
Cable specifications
Power
1.5 mm
2
(0.0023 in.
2
) < 90 m (98 yd)
2 mm
2
(0.0031 in.
2
) < 100 m (109 yd)
CAN bus
Velos cable, min. 0.34 mm
2
(0.0005 in.
2
) twisted pair shielded < 90 m (98 yd)
Antenna
Coax RG58. Max. length depending on antenna type.
Outputs
CE approved at cable length < 3 m (10 ft)
Inputs
CE approved at cable length < 3 m (10 ft)
Other
Antennas
Nedap antenna: Single Loop Walk Through, Single Loop Walk Over, VP6011,
VP6012, VP6030, VP6040, VP6041, VP6042 and VP6050.
Detection distance
Varies per antenna
Synchronization
According to ISO 11785
Software
Downloadable by CAN network
Operating temperature range
-10 to 50 °C (14 to 122 °F)
Storage temperature range
-20 to 70 °C (-4 to 158 °F)
Operational relative humidity
< 93% @ -20 to 70 °C (-4 to 158 °F)
Enclosure protection class
IP30. When installed in V-box IP65 (cover and cables installed correctly!)
Maximum allowed environmental
noise level
10 dBµA/m quasi peak, according to CISPR 16-1-1
Maximum allowed conducted noise
According to EN55032: 2015
Certifications
CE, EAC, FCC, IC and KCC