UPASS ACCESS | INSTALLATION GUIDE
Reader Configuration
14/23
Byte 8-12:
TAGNO TAGNO=Tag number
Examples:
NEDAP UHF XS:
Output: 4E10 3FFF C415
A87C BD51 8000
NEDAP UHF XS decoded:
Output: 4E01 0000 0000
0000 0000 3039
NEDAP UHF XS decoded decimal:
Output: 4E02 0000 0000
0000 0001 2345
NEDAP UHF XS d custcode:
Output: 4E01 0000 0415
A000 0000 3039
NEDAP UHF XS decoded d custcode:
Output: 4E02 0000 0415
A000 0001 2345
5.2.3
RELAY / TIMING
Configure relay output and timing parameters.
Figure 9: Relay / timing settings
Enable 'Automatic relay activation' to activate the relay upon identification. When
disabled the relay can only be activated manually.
The 'Relay hold time' setting is the minimum time the relay is activated.
The 'Vehicle hold time' setting is the time, after a vehicle-id tags has been found, for
which the reader will search for driver-id tags. This setting is only used in the NEDAP
DUAL-ID mode. Introduced in firmware version 2.29.
The (random) RF off time parameter can be used to enable time sharing between
multiple readers on the same frequency.
5.2.4
LED CONTROL
Only for UPASS ACCESS: setup LED control mode.
Automatic mode:
Default the uPASS Access will automatically control the LED.
During stand-by the LED will be BLUE and upon identification it will be GREEN.
These colors can be changed!