TRANSIT Ultimate | installation guide
17/40
4.2
Power supply
The TRANSIT Ultimate can be powered by AC mains or by a 24 VDC power supply.
4.2.1
AC mains
Connect the Mains load and neutral wires to the connector terminals VAC-L and VAC-N. The earth wire should be
connected to the dedicated safety ground connection.
Input voltage:
100 – 240 VAC
Frequency:
60 – 50 Hz
Figure 12: AC mains connections
4.2.2
DC supply input
Connect the DC power supply to the connector terminals as indicated below.
Remove the connector for easy fixing the wires.
Input voltage:
24 VDC ± 10%
Max. input current: 700 mA @ 24 VDC
Figure 13: DC input connections
VAC-L
VAC-N
GROUND
GND
+24VDC