13
5.
Here you can find the following settings:
a.
RFID IP: IP address of RFID reader
b.
RFID Subnet: Subnet address of the RFID reader
c.
RFID Gateway: Gateway of the reader
6.
It is also possible to put the reader in DHCP mode, so it will get an IP-address from a local
DHCP server in the network during power-up. In the ‘Communication Setup’ window the
current IP-address of the reader can be retrieved by using the ‘Get DHCP Status’ button. With
the ‘DHCP Request’ button a manual DHCP request can be performed.
When changing a setting, the setting will be saved when another field is
activated via the ‘Tab’ key or by clicking another field with the mouse.
RFID modes
In this tab, the following settings can be changed:
RFID Protocol: choose either the Icode or ISO15693 protocol, or set it to Combi for both.
Signal: choose the Power and Modulation from 0 to 255, 0 being lowest and 255 being
highest.
MUX: when using a MUX, here you may select how much antennas you’ve connected and
how high the MUX switching time should be in milliseconds.
Synchronization: enable you to synchronize multiple readers.
Power control: Use the sync-In to control the power of the reader.